Code search
Local Verification NeededVerifiedState amendment (amended R507.3.1)
Minn. R. 1309.0507, subp. 1: Section R507, Exterior Decks: IRC Table R507.3.1
Minnesota Rules › Chapter 1309 › 1309.0507 Section R507, Exterior Decks
Verified at the state or federal level. Your local permitting office may adopt or amend it differently. Choose a state to check applicability.
Applicability shown for federal rules only (no state chosen).
In plain language
Minnesota replaces IRC Table R507.3.1 (minimum deck footing size by soil bearing value, live load and tributary area). The table doesn't display well as text here: open the official source.
Staff explanation. The official text below governs.
Official text (excerpt)
Subpart 1. IRC Table R507.3.1. Table R507.3.1 is modified to read as follows: TABLE R507.3.1 MINIMUM FOOTING SIZE FOR DECKS LOAD-BEARING VALUE OF SOILS a, c, d (psf) 1500 e 2000 e LIVE LOAD b (psf) TRIBUTARY AREA (sq. ft.) Side of a square footing (inches) Diameter of a round footing (inches) Thickness (inches) Side of a square footing (inches) Diameter of a round footing (inches) Thickness (inches) 20 12 14 6 12 14 6 40 14 16 6 12 14 6 60 17 19 6 15 17 6 40 80 20 22 7 17 19 6 100 22 25 8 19 21 6 120 24 27 9 21 23 7 140 26 29 10 22 25 8 160 28 31 11 24 27 9 LOAD-BEARING VALUE OF SOILS a, c, d (psf) 2500 e >3000 e LIVE LOAD b (psf) TRIBUTARY AREA (sq. ft.) Side of a square footing (inches) Diameter of a round footing (inches) Thickness (inches) Side of a square footing (inches) Diameter of a round footing (inches) Thickness (inches) 20 12 14 6 12 14 6 40 12 14 6 12 14 6 60 13 15 6 12 14 6 40 80 15 17 6 14 16 6 100 17 19 6 15 17 6 120 19 21 6 17 19 6 140 20 23 7 18 21 6 160 21 24 8 20 22 7 For SI: 1 inch = 25.4 mm, 1 square foot = 0.0929 m 2 , 1 pound per square foot = 0.0479 kPa. a Interpolation permitted, extrapolation not permitted. b Live load = 40 psf, dead load = 10 psf. c Assumes minimum square footing to be 12 inches x 12 inches x 6 inches for a 6 x 6 post. d If the support is a brick or CMU pier, the footing shall have a minimum 2-inch projection on all sides. e Area, in square feet, of deck surface supported by post and footings.
Source
- Publication
- Minnesota Rules, chapter 1309: Adoption of the International Residential Code
- Edition
- 2020 Minnesota State Building Code
- Publisher
- Minnesota Department of Labor and Industry (Office of the Revisor)
- Section
- Minn. R. 1309.0507, subp. 1
- Page
- Online rule: cite by part and subpart; there are no page numbers.
- Effective
- Mar 31, 2020
- Last verified
- Nov 22, 2026
- Rights
- Official government text (law). Official text of Minnesota Rules (state law) from the Office of the Revisor. Built2Bid shows short per-subpart excerpts of Minnesota's own amendments with the citation and a link. The incorporated ICC model code text is not reproduced.
Verification history
Report a problem
Educational information only. Building codes and licensing requirements vary by jurisdiction and may change. Verify requirements with the applicable authority having jurisdiction before beginning work.