29 CFR 1926.451(a): General requirements: Capacity
29 CFR Part 1926 › § 1926.451 General requirements
On file, but the text or how it applies here hasn't been fully verified yet. Your state runs an OSHA-approved State Plan. Its standards govern and must be at least as effective as the federal rule shown.
Applicability shown for Indiana.
Official text
(a) Capacity. (1) Except as provided in paragraphs (a)(2), (a)(3), (a)(4), (a)(5) and (g) of this section, each scaffold and scaffold component shall be capable of supporting, without failure, its own weight and at least 4 times the maximum intended load applied or transmitted to it.
(2) Direct connections to roofs and floors, and counterweights used to balance adjustable suspension scaffolds, shall be capable of resisting at least 4 times the tipping moment imposed by the scaffold operating at the rated load of the hoist, or 1.5 (minimum) times the tipping moment imposed by the scaffold operating at the stall load of the hoist, whichever is greater.
(3) Each suspension rope, including connecting hardware, used on non-adjustable suspension scaffolds shall be capable of supporting, without failure, at least 6 times the maximum intended load applied or transmitted to that rope.
(4) Each suspension rope, including connecting hardware, used on adjustable suspension scaffolds shall be capable of supporting, without failure, at least 6 times the maximum intended load applied or transmitted to that rope with the scaffold operating at either the rated load of the hoist, or 2 (minimum) times the stall load of the hoist, whichever is greater.
(5) The stall load of any scaffold hoist shall not exceed 3 times its rated load.
(6) Scaffolds shall be designed by a qualified person and shall be constructed and loaded in accordance with that design. Non-mandatory appendix A to this subpart contains examples of criteria that will enable an employer to comply with paragraph (a) of this section.
Source
- Publication
- Safety and Health Regulations for Construction
- Edition
- eCFR 2026-11-19
- Publisher
- OSHA (U.S. Department of Labor) via eCFR
- Section
- 29 CFR 1926.451(a)
- Page
- Online regulation: cite by section and paragraph; there are no page numbers.
- Effective
- Not on file
- Last verified
- Nov 22, 2026
- Rights
- Public domain (U.S. Government work). Works of the U.S. Government are not subject to copyright (17 U.S.C. 105). Text is reproduced from the eCFR, which is an editorial compilation and not the official legal edition (the annual CFR and Federal Register are).
Verification history
Report a problem
Educational information only. Building codes and licensing requirements vary by jurisdiction and may change. Verify requirements with the applicable authority having jurisdiction before beginning work.