Skip to content
Built2Bid
Code search
Verified for Selected JurisdictionVerified

29 CFR 1926.502(b): Fall protection systems criteria and practices: Guardrail systems

29 CFR Part 1926 › § 1926.502 Fall protection systems criteria and practices

The adopted requirement and the jurisdiction were confirmed from the official sources below. Verified from the official source.

Applicability shown for Kansas.

In plain language

Guardrail systems: the top edge of the top rail must be 42 inches, plus or minus 3 inches, above the walking/working level, with midrails or equivalent and strength requirements.

Staff explanation. The official text below governs.

Official text

(b) Guardrail systems. Guardrail systems and their use shall comply with the following provisions: (1) Top edge height of top rails, or equivalent guardrail system members, shall be 42 inches (1.1 m) plus or minus 3 inches (8 cm) above the walking/working level. When conditions warrant, the height of the top edge may exceed the 45-inch height, provided the guardrail system meets all other criteria of this paragraph. When employees are using stilts, the top edge height of the top rail, or equivalent member, shall be increased an amount equal to the height of the stilts. (2) Midrails, screens, mesh, intermediate vertical members, or equivalent intermediate structural members shall be installed between the top edge of the guardrail system and the walking/working surface when there is no wall or parapet wall at least 21 inches (53 cm) high. (i) Midrails, when used, shall be installed at a height midway between the top edge of the guardrail system and the walking/working level. (ii) Screens and mesh, when used, shall extend from the top rail to the walking/working level and along the entire opening between top rail supports. (iii) Intermediate members (such as balusters), when used between posts, shall be not more than 19 inches (48 cm) apart. (iv) Other structural members (such as additional midrails and architectural panels) shall be installed such that there are no openings in the guardrail system that are more than 19 inches (.5 m) wide. (3) Guardrail systems shall be capable of withstanding, without failure, a force of at least 200 pounds (890 N) applied within 2 inches (5.1 cm) of the top edge, in any outward or downward direction, at any point along the top edge. (4) When the 200 pound (890 N) test load specified in paragraph (b)(3) of this section is applied in a downward direction, the top edge of the guardrail shall not deflect to a height less than 39 inches (1.0 m) above the walking/working level. Guardrail system components selected and constructed in accordance with the appendix B to subpart M of this part will be deemed to meet this requirement. (5) Midrails, screens, mesh, intermediate vertical members, solid panels, and equivalent structural members shall be capable of withstanding, without failure, a force of at least 150 pounds (666 N) applied in any downward or outward direction at any point along the midrail or other member. (6) Guardrail systems shall be so surfaced as to prevent injury to an employee from punctures or lacerations, and to prevent snagging of clothing. (7) The ends of all top rails and midrails shall not overhang the terminal posts, except where such overhang does not constitute a projection hazard. (8) Steel banding and plastic banding shall not be used as top rails or midrails. (9) Top rails and midrails shall be at least one-quarter inch (0.6 cm) nominal diameter or thickness to prevent cuts and lacerations. If wire rope is used for top rails, it shall be flagged at not more than 6-foot (1.8 m) intervals with high-visibility material. (10) When guardrail systems are used at hoisting areas, a chain, gate or removable guardrail section shall be placed across the access opening between guardrail sections when hoisting operations are not taking place. (11) When guardrail systems are used at holes, they shall be erected on all unprotected sides or edges of the hole. (12) When guardrail systems are used around holes used for the passage of materials, the hole shall have not more than two sides provided with removable guardrail sections to allow the passage of materials. When the hole is not in use, it shall be closed over with a cover, or a guardrail system shall be provided along all unprotected sides or edges. (13) When guardrail systems are used around holes which are used as points of access (such as ladderways), they shall be provided with a gate, or be so offset that a person cannot walk directly into the hole. (14) Guardrail systems used on ramps and runways shall be erected along each unprotected side or edge. (15) Manila, plastic or synthetic rope being used for top rails or midrails shall be inspected as frequently as necessary to ensure that it continues to meet the strength requirements of paragraph (b)(3) of this section.

Source

Publication
Safety and Health Regulations for Construction
Edition
eCFR 2026-11-19
Publisher
OSHA (U.S. Department of Labor) via eCFR
Section
29 CFR 1926.502(b)
Page
Online regulation: cite by section and paragraph; there are no page numbers.
Effective
Not on file
Last verified
Nov 22, 2026
Rights
Public domain (U.S. Government work). Works of the U.S. Government are not subject to copyright (17 U.S.C. 105). Text is reproduced from the eCFR, which is an editorial compilation and not the official legal edition (the annual CFR and Federal Register are).

Verification history

  • Nov 22, 2026 · Section: Read in the official publication, verified · source
  • Nov 22, 2026 · Publication: Read in the official publication, verified · source
Report a problem

Educational information only. Building codes and licensing requirements vary by jurisdiction and may change. Verify requirements with the applicable authority having jurisdiction before beginning work.