Minnesota amends IRC R311.7.2: minimum stairway headroom is 6 feet 8 inches, with listed exceptions.
Staff explanation. The official text below governs.
Official text (excerpt)
Subp. 3. IRC section R311.7.2, Headroom. Section R311.7.2 is amended to read as follows: R311.7.2 Headroom. The minimum headroom in all parts of the stairway shall not be less than 6 feet 8 inches (2032 mm) measured vertically from the sloped line adjoining the tread nosing or from the floor surface of the landing or platform on that portion of the stairway. Exceptions: 1. Where the nosings of treads at the side of a flight extend under the edge of a floor opening through which the stair passes, the floor opening shall be allowed to project horizontally into the required headroom a maximum of 4-3/4 inches (121 mm). 2. The minimum headroom for existing buildings shall be in accordance with Section R305.2.2. 3. The headroom for spiral stairways shall be in accordance with Section R311.7.10.1.
Source
- Publication
- Minnesota Rules, chapter 1309: Adoption of the International Residential Code
- Edition
- 2020 Minnesota State Building Code
- Publisher
- Minnesota Department of Labor and Industry (Office of the Revisor)
- Section
- Minn. R. 1309.0311, subp. 3
- Page
- Online rule: cite by part and subpart; there are no page numbers.
- Effective
- Mar 31, 2020
- Last verified
- Nov 22, 2026
- Rights
- Official government text (law). Official text of Minnesota Rules (state law) from the Office of the Revisor. Built2Bid shows short per-subpart excerpts of Minnesota's own amendments with the citation and a link. The incorporated ICC model code text is not reproduced.
Verification history
Report a problem
Educational information only. Building codes and licensing requirements vary by jurisdiction and may change. Verify requirements with the applicable authority having jurisdiction before beginning work.