Verified at the state or federal level. Your local permitting office may adopt or amend it differently. Which city, county or township is the project in? Pick it under “Where is the project?” to check. The Minnesota State Building Code is the minimum standard statewide, but DLI states it is not enforceable by a municipality unless adopted by local ordinance. Confirm with the city, township or county building official for the project. Tell us where the project is
Applicability shown for Minnesota.
In plain language
Minnesota amends IRC R403.1.6 (foundation anchorage): anchor bolt size, spacing and placement for sill and sole plates.
Staff explanation. The official text below governs.
Official text (excerpt)
Subp. 2. IRC section R403.1.6. IRC Section R403.1.6 is amended to read as follows: R403.1.6 Foundation anchorage. Sill plates and walls supported directly on continuous foundations shall be anchored to the foundation in accordance with this section. Wood sole plates at all exterior walls on monolithic slabs, wood sole plates of braced wall panels at building interiors on monolithic slabs, and all wood sill plates shall be anchored to the foundation with anchor bolts spaced a maximum of 6 feet (1829 mm) on center. Bolts shall be at least 1/2-inch (12.7 mm) in diameter and shall extend a minimum of 7 inches (178 mm) into concrete or grouted cells of concrete masonry units. A nut and washer shall be tightened on each bolt. There shall be a minimum of two bolts per plate section with one bolt located not more than 12 inches (305 mm) or less than 7 bolt diameters from each end of the plate section. Interior bearing wall sole plates on monolithic slab foundation that are not part of a braced wall panel shall be positively anchored with approved fasteners. Sill plates and sole plates shall be protected against decay and termites where required by Sections R317 and R318. Cold-formed steel framing systems shall be fastened to the wood sill plates or anchored directly to the foundation as required in Section R505.3.1 or R603.1.1. When vertical reinforcing is required by other sections of this code, the foundation anchor bolts shall be within 8 inches (203 mm) of the vertical reinforcing. All anchor bolts installed in masonry shall be grouted in place with at least 1-inch (25 mm) of grout measured from the inside face of the masonry and the anchor bolt. Exceptions: 1. Foundation anchor straps spaced as required to provide equivalent anchorage to 1/2-inch diameter (12.7 mm) anchor bolts. When vertical reinforcing is required by other sections of this code, the foundation anchor straps shall align with the reinforcing. 2. Walls 24 inches (609.6 mm) total length or shorter connecting offset braced wall panels shall be anchored to the foundation with a minimum of one anchor bolt located in the center third of the plate section and shall be attached to adjacent braced wall panels according to Figure R602.10.5 at corners. 3. Walls 12 inches (304.8 mm) total length or shorter connecting offset braced wall panels shall be permitted to be connected to the foundation without anchor bolts. The wall shall be attached to adjacent braced wall panels according to Figure R602.10.5 at corners.
Source
Publication
Minnesota Rules, chapter 1309: Adoption of the International Residential Code
Edition
2020 Minnesota State Building Code
Publisher
Minnesota Department of Labor and Industry (Office of the Revisor)
Section
Minn. R. 1309.0403, subp. 2
Page
Online rule: cite by part and subpart; there are no page numbers.
Effective
Mar 31, 2020
Last verified
Nov 22, 2026
Rights
Official government text (law). Official text of Minnesota Rules (state law) from the Office of the Revisor. Built2Bid shows short per-subpart excerpts of Minnesota's own amendments with the citation and a link. The incorporated ICC model code text is not reproduced.
Nov 22, 2026 · Section: Read in the official publication, verified · source
Nov 22, 2026 · Publication: Read in the official publication, verified · source
Report a problem
Educational information only. Building codes and licensing requirements vary by jurisdiction and may change. Verify requirements with the applicable authority having jurisdiction before beginning work.