Code search
Under ReviewVerified
29 CFR 1926.651(k): Specific excavation requirements: Inspections
29 CFR Part 1926 › § 1926.651 Specific excavation requirements
On file, but the text or how it applies here hasn't been fully verified yet. Your state runs an OSHA-approved State Plan. Its standards govern and must be at least as effective as the federal rule shown.
Applicability shown for Virginia.
In plain language
A competent person must inspect excavations, adjacent areas and protective systems daily before work starts and as needed, and after rainstorms or other hazard-increasing events.
Staff explanation. The official text below governs.
Official text
(k) Inspections. (1) Daily inspections of excavations, the adjacent areas, and protective systems shall be made by a competent person for evidence of a situation that could result in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions. An inspection shall be conducted by the competent person prior to the start of work and as needed throughout the shift. Inspections shall also be made after every rainstorm or other hazard increasing occurrence. These inspections are only required when employee exposure can be reasonably anticipated.
(2) Where the competent person finds evidence of a situation that could result in a possible cave-in, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions, exposed employees shall be removed from the hazardous area until the necessary precautions have been taken to ensure their safety.
Source
- Publication
- Safety and Health Regulations for Construction
- Edition
- eCFR 2026-11-19
- Publisher
- OSHA (U.S. Department of Labor) via eCFR
- Section
- 29 CFR 1926.651(k)
- Page
- Online regulation: cite by section and paragraph; there are no page numbers.
- Effective
- Not on file
- Last verified
- Nov 22, 2026
- Rights
- Public domain (U.S. Government work). Works of the U.S. Government are not subject to copyright (17 U.S.C. 105). Text is reproduced from the eCFR, which is an editorial compilation and not the official legal edition (the annual CFR and Federal Register are).
Verification history
Report a problem
Educational information only. Building codes and licensing requirements vary by jurisdiction and may change. Verify requirements with the applicable authority having jurisdiction before beginning work.