Codes & Regulations
Find the codes that apply to your project, with the source, edition and when we last checked it.
We can't give a verified answer to this yet.
Unable to verify the applicable requirement from the available official sources. Confirm with your local building department or authority having jurisdiction.
Residential code in force in Indiana
International Residential Code
2018 · in effect Dec 26, 2019
Official reference availableOfficial source
EPA Lead Renovation, Repair and Painting Rule (40 CFR Part 745)
eCFR 2026-11-19
Searchable hereOfficial source
Statewide code references are available. Confirm your local jurisdiction to check for additional requirements or amendments.
Related searches
- stairs · try riser, tread, handrail, guard
- riser · try tread, handrail, guard, headroomBuilding-code stair rules (IRC R311.7 and state amendments) cover the finished building. OSHA 29 CFR 1926.1052 covers temporary stairways workers use during construction. They are different requirements.
- deck · try footing, ledger, guard, stairs
Building codes
What the adopted building, residential, electrical, mechanical or energy code requires.
- Under Review
2018 IRC Section R311.7: Stairways
IRC · 2018
Section title only. Read the requirement in the official source.
Edition and verification details
On file, but the text or how it applies here hasn't been fully verified yet. The section text has not been verified yet.
- Jurisdiction
- Indiana
- Source
- 2018 International Residential Code
- Edition
- 2018
- Section
- 2018 IRC Section R311.7
- Effective
- Dec 26, 2019
- Last verified
- Not verified yet
- Trades
- decks, framing, interior-remodeling, basements, additions
- Page
- Page numbers differ between print, PDF and online formats; Built2Bid cites sections only.
Report a problem
- Under Review
2018 IRC Section R507: Exterior decks
IRC · 2018
Section title only. Read the requirement in the official source.
Edition and verification details
On file, but the text or how it applies here hasn't been fully verified yet. The section text has not been verified yet.
- Jurisdiction
- Indiana
- Source
- 2018 International Residential Code
- Edition
- 2018
- Section
- 2018 IRC Section R507
- Effective
- Dec 26, 2019
- Last verified
- Not verified yet
- Trades
- decks
- Page
- Page numbers differ between print, PDF and online formats; Built2Bid cites sections only.
Report a problem
- Under Review
2018 IRC Section R312: Guards and window fall protection
IRC · 2018
Section title only. Read the requirement in the official source.
Edition and verification details
On file, but the text or how it applies here hasn't been fully verified yet. The section text has not been verified yet.
- Jurisdiction
- Indiana
- Source
- 2018 International Residential Code
- Edition
- 2018
- Section
- 2018 IRC Section R312
- Effective
- Dec 26, 2019
- Last verified
- Not verified yet
- Trades
- decks, framing, windows-doors
- Page
- Page numbers differ between print, PDF and online formats; Built2Bid cites sections only.
Report a problem
Worker safety (OSHA)
Rules that protect workers on the job. They do not replace the building code for the finished work.
- Under Review
29 CFR 1926.1052(c): Stairways: Stairrails and handrails
29 CFR 1926 · eCFR 2026-11-19
Construction stairways with four or more risers or more than 30 inches of rise need at least one handrail and stairrails on unprotected sides, with height and strength requirements.
Edition and verification details
On file, but the text or how it applies here hasn't been fully verified yet. Your state runs an OSHA-approved State Plan. Its standards govern and must be at least as effective as the federal rule shown.
- Jurisdiction
- Federal
- Source
- Safety and Health Regulations for Construction
- Edition
- eCFR 2026-11-19
- Section
- 29 CFR 1926.1052(c)
- Effective
- Not on file
- Last verified
- Nov 22, 2026
- Trades
- All trades
- Page
- Online regulation: cite by section and paragraph; there are no page numbers.
Official sourceReport a problem
- Under Review
29 CFR 1926.1052(a): Stairways: General
29 CFR 1926 · eCFR 2026-11-19
Construction stairways (the ones workers use during construction): landing size, a 30 to 50 degree slope, and riser heights and tread depths that are uniform within each flight, varying no more than 1/4 inch. These are worker-safety rules, not the building code rules for the finished home.
Edition and verification details
On file, but the text or how it applies here hasn't been fully verified yet. Your state runs an OSHA-approved State Plan. Its standards govern and must be at least as effective as the federal rule shown.
- Jurisdiction
- Federal
- Source
- Safety and Health Regulations for Construction
- Edition
- eCFR 2026-11-19
- Section
- 29 CFR 1926.1052(a)
- Effective
- Not on file
- Last verified
- Nov 22, 2026
- Trades
- All trades
- Page
- Online regulation: cite by section and paragraph; there are no page numbers.
Official sourceReport a problem
- Under Review
29 CFR 1926.1052(b): Stairways: Temporary service
29 CFR 1926 · eCFR 2026-11-19
Edition and verification details
On file, but the text or how it applies here hasn't been fully verified yet. Your state runs an OSHA-approved State Plan. Its standards govern and must be at least as effective as the federal rule shown.
- Jurisdiction
- Federal
- Source
- Safety and Health Regulations for Construction
- Edition
- eCFR 2026-11-19
- Section
- 29 CFR 1926.1052(b)
- Effective
- Not on file
- Last verified
- Nov 22, 2026
- Trades
- All trades
- Page
- Online regulation: cite by section and paragraph; there are no page numbers.
Official sourceReport a problem
- Under Review
29 CFR 1926.502(b): Fall protection systems criteria and practices: Guardrail systems
29 CFR 1926 · eCFR 2026-11-19
Guardrail systems: the top edge of the top rail must be 42 inches, plus or minus 3 inches, above the walking/working level, with midrails or equivalent and strength requirements.
Edition and verification details
On file, but the text or how it applies here hasn't been fully verified yet. Your state runs an OSHA-approved State Plan. Its standards govern and must be at least as effective as the federal rule shown.
- Jurisdiction
- Federal
- Source
- Safety and Health Regulations for Construction
- Edition
- eCFR 2026-11-19
- Section
- 29 CFR 1926.502(b)
- Effective
- Not on file
- Last verified
- Nov 22, 2026
- Trades
- All trades
- Page
- Online regulation: cite by section and paragraph; there are no page numbers.
Official sourceReport a problem
- Under Review
29 CFR 1926.502(d): Fall protection systems criteria and practices: Personal fall arrest systems
29 CFR 1926 · eCFR 2026-11-19
Personal fall arrest systems: anchorages, connectors, harnesses and lanyards must meet strength and use requirements, and the system must limit free fall and arrest forces.
Edition and verification details
On file, but the text or how it applies here hasn't been fully verified yet. Your state runs an OSHA-approved State Plan. Its standards govern and must be at least as effective as the federal rule shown.
- Jurisdiction
- Federal
- Source
- Safety and Health Regulations for Construction
- Edition
- eCFR 2026-11-19
- Section
- 29 CFR 1926.502(d)
- Effective
- Not on file
- Last verified
- Nov 22, 2026
- Trades
- All trades
- Page
- Online regulation: cite by section and paragraph; there are no page numbers.
Official sourceReport a problem
- Under Review
29 CFR 1926.502(k): Fall protection systems criteria and practices: Fall protection plan
29 CFR 1926 · eCFR 2026-11-19
A fall protection plan is an option only for leading-edge work, precast concrete erection or residential construction when the employer can show conventional fall protection is infeasible or creates a greater hazard. It must be written by a qualified person and kept at the job site.
Edition and verification details
On file, but the text or how it applies here hasn't been fully verified yet. Your state runs an OSHA-approved State Plan. Its standards govern and must be at least as effective as the federal rule shown.
- Jurisdiction
- Federal
- Source
- Safety and Health Regulations for Construction
- Edition
- eCFR 2026-11-19
- Section
- 29 CFR 1926.502(k)
- Effective
- Not on file
- Last verified
- Nov 22, 2026
- Trades
- All trades
- Page
- Online regulation: cite by section and paragraph; there are no page numbers.
Official sourceReport a problem
- Under Review
29 CFR 1926.451(g): General requirements: Fall protection
29 CFR 1926 · eCFR 2026-11-19
Workers on a scaffold more than 10 feet above a lower level must be protected from falling, with the type of protection depending on the scaffold.
Edition and verification details
On file, but the text or how it applies here hasn't been fully verified yet. Your state runs an OSHA-approved State Plan. Its standards govern and must be at least as effective as the federal rule shown.
- Jurisdiction
- Federal
- Source
- Safety and Health Regulations for Construction
- Edition
- eCFR 2026-11-19
- Section
- 29 CFR 1926.451(g)
- Effective
- Not on file
- Last verified
- Nov 22, 2026
- Trades
- general-contracting, masonry, painting, pressure-washing, roofing, siding, soft-washing
- Page
- Online regulation: cite by section and paragraph; there are no page numbers.
Official sourceReport a problem
- Under Review
29 CFR 1926.850: Preparatory operations
29 CFR 1926 · eCFR 2026-11-19
Edition and verification details
On file, but the text or how it applies here hasn't been fully verified yet. Your state runs an OSHA-approved State Plan. Its standards govern and must be at least as effective as the federal rule shown.
- Jurisdiction
- Federal
- Source
- Safety and Health Regulations for Construction
- Edition
- eCFR 2026-11-19
- Section
- 29 CFR 1926.850
- Effective
- Not on file
- Last verified
- Nov 22, 2026
- Trades
- commercial-remodeling, demolition, general-contracting, interior-remodeling
- Page
- Online regulation: cite by section and paragraph; there are no page numbers.
Official sourceReport a problem
Environmental rules (EPA)
Federal environmental work-practice rules.
- Local Verification Needed
40 CFR 745.82: Applicability
40 CFR 745 · eCFR 2026-11-19
The federal RRP rule applies to renovations for compensation in target housing and child-occupied facilities, except where the affected components were found free of lead-based paint by a certified inspector or risk assessor, by a certified renovator using an EPA-recognized test kit, or by an EPA-recognized lab testing paint chips (other listed exceptions apply).
Edition and verification details
Verified at the state or federal level. Your local permitting office may adopt or amend it differently. Federal rule. State programs can add to it or run their own version. Federal rule for paid renovation in pre-1978 target housing and child-occupied facilities. Some states and tribes run EPA-authorized programs with their own certification.
- Jurisdiction
- Federal
- Source
- Lead-Based Paint Poisoning Prevention in Certain Residential Structures
- Edition
- eCFR 2026-11-19
- Section
- 40 CFR 745.82
- Effective
- Not on file
- Last verified
- Nov 22, 2026
- Trades
- bathrooms, exterior-remodeling, general-contracting, handyman, interior-remodeling, kitchens, painting, siding, windows-doors
- Page
- Online regulation: cite by section and paragraph; there are no page numbers.
Official sourceReport a problem
Report a problem
Available Indiana codes
Rules of the Fire Prevention and Building Safety Commission (675 IAC) are in force everywhere in Indiana. The state reviews plans for commercial (Class 1) buildings; local units must require compliance and handle local permitting/inspection, including for one- and two-family homes (Class 2). One code applies statewide.
Residential
International Residential Code
2018 · in effect Dec 26, 2019
Official reference availableOfficial source
EPA Lead Renovation, Repair and Painting Rule (40 CFR Part 745)
eCFR 2026-11-19
Searchable hereOfficial sourceSearch this code
Building
International Building Code
2012 · in effect Dec 1, 2014
Official reference availableOfficial source
Electrical
Indiana Electrical Code (2009 Edition in effect until repla…
Current
Under reviewOfficial source
Plumbing
International Plumbing Code
2006 · in effect Dec 24, 2012
Official reference availableOfficial source
Mechanical / fuel gas
International Fuel Gas Code
2012 · in effect Dec 1, 2014
Official reference availableOfficial source
International Mechanical Code
2012 · in effect Dec 1, 2014
Official reference availableOfficial source
Energy
ASHRAE Standard 90.1
2007 · in effect May 6, 2010
Official reference availableOfficial source
Fire
International Fire Code
2012 · in effect Dec 1, 2014
Official reference availableOfficial source
Worker safety
OSHA Construction Standards (29 CFR Part 1926)
eCFR 2026-11-19
Searchable hereOfficial sourceSearch this code
OSHA Recordkeeping and Reporting (29 CFR Part 1904)
eCFR 2026-11-19
Searchable hereOfficial sourceSearch this code
OSHA-approved State Plan
eCFR 2026-11-19
Searchable hereOfficial sourceSearch this code
Other
FMCSA Motor Carrier Safety Regulations (49 CFR)
eCFR 2026-11-19
Searchable hereOfficial sourceSearch this code
Learn it
Flashcards, quizzes and practice exams on jobsite safety, codebook navigation and running a contracting business.
How answers work
- Answers come only from official sources we have checked. We never make up code text, section numbers, page numbers or dates.
- Copyrighted model codes (like the IRC and IBC) are cited by section and linked to the official copy. We don't reproduce them.
- A statewide result is not a full local compliance check. Your city, township or county can add requirements.
Educational information only. Building codes and licensing requirements vary by jurisdiction and may change. Verify requirements with the applicable authority having jurisdiction before beginning work.