Codes & Regulations
Find the codes that apply to your project, with the source, edition and when we last checked it.
Quick answer
- Verified for Selected Jurisdiction
29 CFR 1926.501(c): Duty to have fall protection: Protection from falling objects
29 CFR 1926 · eCFR 2026-11-19
Edition and verification details
The adopted requirement and the jurisdiction were confirmed from the official sources below. Verified from the official source.
- Jurisdiction
- Federal
- Source
- Safety and Health Regulations for Construction
- Edition
- eCFR 2026-11-19
- Section
- 29 CFR 1926.501(c)
- Effective
- Not on file
- Last verified
- Nov 22, 2026
- Trades
- All trades
- Page
- Online regulation: cite by section and paragraph; there are no page numbers.
Official sourceReport a problem
Building codes
What the adopted building, residential, electrical, mechanical or energy code requires.
- Local Verification NeededState amendment
Minn. R. 1309.0312, subp. 2: Section R312, Guards and Window Fall Protection: IRC section R312.2, Window fall protection
Minn. R. 1309 · 2020 Minnesota State Building Code
Minnesota amends the IRC window fall protection section (R312.2).
Edition and verification details
Verified at the state or federal level. Your local permitting office may adopt or amend it differently. Choose a state to check applicability.
- Jurisdiction
- Minnesota
- Source
- Minnesota Rules, chapter 1309: Adoption of the International Residential Code
- Edition
- 2020 Minnesota State Building Code
- Section
- Minn. R. 1309.0312, subp. 2
- Effective
- Not on file
- Last verified
- Nov 22, 2026
- Trades
- additions, basements, decks, exterior-remodeling, framing, garages, general-contracting, interior-remodeling, windows-doors
- Page
- Online rule: cite by part and subpart; there are no page numbers.
Official sourceReport a problem
- Local Verification NeededState amendment
Minn. R. 1309.0312, subp. 1: Section R312, Guards and Window Fall Protection: IRC section R312.1.1, Where required
Minn. R. 1309 · 2020 Minnesota State Building Code
Minnesota amends IRC R312.1.1: guards are required along open sides of floors, stairs, ramps and landings more than 30 inches above the floor or grade below. Insect screening is not a guard.
Edition and verification details
Verified at the state or federal level. Your local permitting office may adopt or amend it differently. Choose a state to check applicability.
- Jurisdiction
- Minnesota
- Source
- Minnesota Rules, chapter 1309: Adoption of the International Residential Code
- Edition
- 2020 Minnesota State Building Code
- Section
- Minn. R. 1309.0312, subp. 1
- Effective
- Not on file
- Last verified
- Nov 22, 2026
- Trades
- additions, basements, decks, exterior-remodeling, framing, garages, general-contracting, interior-remodeling, windows-doors
- Page
- Online rule: cite by part and subpart; there are no page numbers.
Official sourceReport a problem
- Under Review
2018 IRC Section R312: Guards and window fall protection
IRC · 2018
Section title only. Read the requirement in the official source.
Edition and verification details
Verified at the state or federal level. Your local permitting office may adopt or amend it differently. Choose a state to check applicability.
- Jurisdiction
- Model code (applies only where adopted)
- Source
- 2018 International Residential Code
- Edition
- 2018
- Section
- 2018 IRC Section R312
- Effective
- Not on file
- Last verified
- Not verified yet
- Trades
- decks, framing, windows-doors
- Page
- Page numbers differ between print, PDF and online formats; Built2Bid cites sections only.
Report a problem
- Local Verification NeededState amendment
Minn. R. 1309.0903: Section R903, Weather Protection
Minn. R. 1309 · 2020 Minnesota State Building Code
Minnesota amends IRC R903.2.1: flashing at wall and roof intersections, slope changes and roof openings, plus kick-out flashing where a sloped roof eave meets a sidewall (required when re-siding, not when only re-roofing).
Edition and verification details
Verified at the state or federal level. Your local permitting office may adopt or amend it differently. Choose a state to check applicability.
- Jurisdiction
- Minnesota
- Source
- Minnesota Rules, chapter 1309: Adoption of the International Residential Code
- Edition
- 2020 Minnesota State Building Code
- Section
- Minn. R. 1309.0903
- Effective
- Not on file
- Last verified
- Nov 22, 2026
- Trades
- general-contracting, roofing
- Page
- Online rule: cite by part and subpart; there are no page numbers.
Official sourceReport a problem
- Under Review
2018 IRC Section R903: Weather protection
IRC · 2018
Section title only. Read the requirement in the official source.
Edition and verification details
Verified at the state or federal level. Your local permitting office may adopt or amend it differently. Choose a state to check applicability.
- Jurisdiction
- Model code (applies only where adopted)
- Source
- 2018 International Residential Code
- Edition
- 2018
- Section
- 2018 IRC Section R903
- Effective
- Not on file
- Last verified
- Not verified yet
- Trades
- roofing
- Page
- Page numbers differ between print, PDF and online formats; Built2Bid cites sections only.
Report a problem
- Under Review
2018 IRC Section R317: Protection of wood and wood-based products against decay
IRC · 2018
Section title only. Read the requirement in the official source.
Edition and verification details
Verified at the state or federal level. Your local permitting office may adopt or amend it differently. Choose a state to check applicability.
- Jurisdiction
- Model code (applies only where adopted)
- Source
- 2018 International Residential Code
- Edition
- 2018
- Section
- 2018 IRC Section R317
- Effective
- Not on file
- Last verified
- Not verified yet
- Trades
- decks, framing
- Page
- Page numbers differ between print, PDF and online formats; Built2Bid cites sections only.
Report a problem
- Local Verification NeededState amendment
Minn. R. 1309.0403, subp. 1: Section R403, Footings: IRC section R403.1.4.1
Minn. R. 1309 · 2020 Minnesota State Building Code
Minnesota amends IRC R403.1.4.1 (frost protection): footings can't bear on frozen soil, and permanent supports must be protected from frost by one of the listed methods.
Edition and verification details
Verified at the state or federal level. Your local permitting office may adopt or amend it differently. Choose a state to check applicability.
- Jurisdiction
- Minnesota
- Source
- Minnesota Rules, chapter 1309: Adoption of the International Residential Code
- Edition
- 2020 Minnesota State Building Code
- Section
- Minn. R. 1309.0403, subp. 1
- Effective
- Not on file
- Last verified
- Nov 22, 2026
- Trades
- additions, concrete, decks, foundations, garages, general-contracting, pole-barns
- Page
- Online rule: cite by part and subpart; there are no page numbers.
Official sourceReport a problem
Worker safety (OSHA)
Rules that protect workers on the job. They do not replace the building code for the finished work.
- Verified for Selected Jurisdiction
29 CFR 1926.502(k): Fall protection systems criteria and practices: Fall protection plan
29 CFR 1926 · eCFR 2026-11-19
A fall protection plan is an option only for leading-edge work, precast concrete erection or residential construction when the employer can show conventional fall protection is infeasible or creates a greater hazard. It must be written by a qualified person and kept at the job site.
Edition and verification details
The adopted requirement and the jurisdiction were confirmed from the official sources below. Verified from the official source.
- Jurisdiction
- Federal
- Source
- Safety and Health Regulations for Construction
- Edition
- eCFR 2026-11-19
- Section
- 29 CFR 1926.502(k)
- Effective
- Not on file
- Last verified
- Nov 22, 2026
- Trades
- All trades
- Page
- Online regulation: cite by section and paragraph; there are no page numbers.
Official sourceReport a problem
- Verified for Selected Jurisdiction
29 CFR 1926.501(b): Duty to have fall protection: paragraph (b)
29 CFR 1926 · eCFR 2026-11-19
Employers must protect workers from falls of 6 feet or more to a lower level, using guardrails, safety nets or personal fall arrest systems, with specific options for leading edges, holes, low-slope and steep roofs, and residential construction (where a written fall protection plan is allowed only when the employer can show the usual systems are infeasible or more hazardous).
Edition and verification details
The adopted requirement and the jurisdiction were confirmed from the official sources below. Verified from the official source.
- Jurisdiction
- Federal
- Source
- Safety and Health Regulations for Construction
- Edition
- eCFR 2026-11-19
- Section
- 29 CFR 1926.501(b)
- Effective
- Not on file
- Last verified
- Nov 22, 2026
- Trades
- All trades
- Page
- Online regulation: cite by section and paragraph; there are no page numbers.
Official sourceReport a problem
- Verified for Selected Jurisdiction
29 CFR 1926.501(a): Duty to have fall protection: General
29 CFR 1926 · eCFR 2026-11-19
Sets out when employers must provide fall protection and that the systems must meet 29 CFR 1926.502.
Edition and verification details
The adopted requirement and the jurisdiction were confirmed from the official sources below. Verified from the official source.
- Jurisdiction
- Federal
- Source
- Safety and Health Regulations for Construction
- Edition
- eCFR 2026-11-19
- Section
- 29 CFR 1926.501(a)
- Effective
- Not on file
- Last verified
- Nov 22, 2026
- Trades
- All trades
- Page
- Online regulation: cite by section and paragraph; there are no page numbers.
Official sourceReport a problem
- Verified for Selected Jurisdiction
29 CFR 1926.502(d): Fall protection systems criteria and practices: Personal fall arrest systems
29 CFR 1926 · eCFR 2026-11-19
Personal fall arrest systems: anchorages, connectors, harnesses and lanyards must meet strength and use requirements, and the system must limit free fall and arrest forces.
Edition and verification details
The adopted requirement and the jurisdiction were confirmed from the official sources below. Verified from the official source.
- Jurisdiction
- Federal
- Source
- Safety and Health Regulations for Construction
- Edition
- eCFR 2026-11-19
- Section
- 29 CFR 1926.502(d)
- Effective
- Not on file
- Last verified
- Nov 22, 2026
- Trades
- All trades
- Page
- Online regulation: cite by section and paragraph; there are no page numbers.
Official sourceReport a problem
- Verified for Selected Jurisdiction
29 CFR 1926.451(g): General requirements: Fall protection
29 CFR 1926 · eCFR 2026-11-19
Workers on a scaffold more than 10 feet above a lower level must be protected from falling, with the type of protection depending on the scaffold.
Edition and verification details
The adopted requirement and the jurisdiction were confirmed from the official sources below. Verified from the official source.
- Jurisdiction
- Federal
- Source
- Safety and Health Regulations for Construction
- Edition
- eCFR 2026-11-19
- Section
- 29 CFR 1926.451(g)
- Effective
- Not on file
- Last verified
- Nov 22, 2026
- Trades
- general-contracting, masonry, painting, pressure-washing, roofing, siding, soft-washing
- Page
- Online regulation: cite by section and paragraph; there are no page numbers.
Official sourceReport a problem
- Verified for Selected Jurisdiction
29 CFR 1926.502(b): Fall protection systems criteria and practices: Guardrail systems
29 CFR 1926 · eCFR 2026-11-19
Guardrail systems: the top edge of the top rail must be 42 inches, plus or minus 3 inches, above the walking/working level, with midrails or equivalent and strength requirements.
Edition and verification details
The adopted requirement and the jurisdiction were confirmed from the official sources below. Verified from the official source.
- Jurisdiction
- Federal
- Source
- Safety and Health Regulations for Construction
- Edition
- eCFR 2026-11-19
- Section
- 29 CFR 1926.502(b)
- Effective
- Not on file
- Last verified
- Nov 22, 2026
- Trades
- All trades
- Page
- Online regulation: cite by section and paragraph; there are no page numbers.
Official sourceReport a problem
- Verified for Selected Jurisdiction
29 CFR 1926.451(a): General requirements: Capacity
29 CFR 1926 · eCFR 2026-11-19
Edition and verification details
The adopted requirement and the jurisdiction were confirmed from the official sources below. Verified from the official source.
- Jurisdiction
- Federal
- Source
- Safety and Health Regulations for Construction
- Edition
- eCFR 2026-11-19
- Section
- 29 CFR 1926.451(a)
- Effective
- Not on file
- Last verified
- Nov 22, 2026
- Trades
- general-contracting, masonry, painting, pressure-washing, roofing, siding, soft-washing
- Page
- Online regulation: cite by section and paragraph; there are no page numbers.
Official sourceReport a problem
- Verified for Selected Jurisdiction
29 CFR 1926.100: Head protection
29 CFR 1926 · eCFR 2026-11-19
Workers exposed to head injury from impact, falling or flying objects, or electrical shock must wear protective helmets.
Edition and verification details
The adopted requirement and the jurisdiction were confirmed from the official sources below. Verified from the official source.
- Jurisdiction
- Federal
- Source
- Safety and Health Regulations for Construction
- Edition
- eCFR 2026-11-19
- Section
- 29 CFR 1926.100
- Effective
- Not on file
- Last verified
- Nov 22, 2026
- Trades
- All trades
- Page
- Online regulation: cite by section and paragraph; there are no page numbers.
Official sourceReport a problem
- Verified for Selected Jurisdiction
29 CFR 1926.651(j): Specific excavation requirements: Protection of employees from loose rock or soil
29 CFR 1926 · eCFR 2026-11-19
Edition and verification details
The adopted requirement and the jurisdiction were confirmed from the official sources below. Verified from the official source.
- Jurisdiction
- Federal
- Source
- Safety and Health Regulations for Construction
- Edition
- eCFR 2026-11-19
- Section
- 29 CFR 1926.651(j)
- Effective
- Not on file
- Last verified
- Nov 22, 2026
- Trades
- basements, concrete, excavation, foundations, general-contracting, landscaping, plumbing, pole-barns
- Page
- Online regulation: cite by section and paragraph; there are no page numbers.
Official sourceReport a problem
- Verified for Selected Jurisdiction
29 CFR 1926.652(a): Requirements for protective systems: Protection of employees in excavations
29 CFR 1926 · eCFR 2026-11-19
Workers in an excavation must be protected from cave-ins by an adequate protective system unless the excavation is entirely in stable rock, or is less than 5 feet deep and a competent person finds no indication of a potential cave-in.
Edition and verification details
The adopted requirement and the jurisdiction were confirmed from the official sources below. Verified from the official source.
- Jurisdiction
- Federal
- Source
- Safety and Health Regulations for Construction
- Edition
- eCFR 2026-11-19
- Section
- 29 CFR 1926.652(a)
- Effective
- Not on file
- Last verified
- Nov 22, 2026
- Trades
- basements, concrete, excavation, foundations, general-contracting, plumbing
- Page
- Online regulation: cite by section and paragraph; there are no page numbers.
Official sourceReport a problem
- Verified for Selected Jurisdiction
29 CFR 1926.651(e): Specific excavation requirements: Exposure to falling loads
29 CFR 1926 · eCFR 2026-11-19
Edition and verification details
The adopted requirement and the jurisdiction were confirmed from the official sources below. Verified from the official source.
- Jurisdiction
- Federal
- Source
- Safety and Health Regulations for Construction
- Edition
- eCFR 2026-11-19
- Section
- 29 CFR 1926.651(e)
- Effective
- Not on file
- Last verified
- Nov 22, 2026
- Trades
- basements, concrete, excavation, foundations, general-contracting, landscaping, plumbing, pole-barns
- Page
- Online regulation: cite by section and paragraph; there are no page numbers.
Official sourceReport a problem
- Verified for Selected Jurisdiction
29 CFR 1926.102(a): Eye and face protection: General
29 CFR 1926 · eCFR 2026-11-19
Edition and verification details
The adopted requirement and the jurisdiction were confirmed from the official sources below. Verified from the official source.
- Jurisdiction
- Federal
- Source
- Safety and Health Regulations for Construction
- Edition
- eCFR 2026-11-19
- Section
- 29 CFR 1926.102(a)
- Effective
- Not on file
- Last verified
- Nov 22, 2026
- Trades
- All trades
- Page
- Online regulation: cite by section and paragraph; there are no page numbers.
Official sourceReport a problem
- Verified for Selected Jurisdiction
29 CFR 1926.404(b): Wiring design and protection: Branch circuits
29 CFR 1926 · eCFR 2026-11-19
On construction sites, temporary 120-volt, single-phase 15- and 20-amp receptacles in use by employees need GFCI protection, or the employer must run an assured equipment grounding conductor program.
Edition and verification details
The adopted requirement and the jurisdiction were confirmed from the official sources below. Verified from the official source.
- Jurisdiction
- Federal
- Source
- Safety and Health Regulations for Construction
- Edition
- eCFR 2026-11-19
- Section
- 29 CFR 1926.404(b)
- Effective
- Not on file
- Last verified
- Nov 22, 2026
- Trades
- All trades
- Page
- Online regulation: cite by section and paragraph; there are no page numbers.
Official sourceReport a problem
- Verified for Selected Jurisdiction
29 CFR 1926.95(a): Criteria for personal protective equipment: Application
29 CFR 1926 · eCFR 2026-11-19
Edition and verification details
The adopted requirement and the jurisdiction were confirmed from the official sources below. Verified from the official source.
- Jurisdiction
- Federal
- Source
- Safety and Health Regulations for Construction
- Edition
- eCFR 2026-11-19
- Section
- 29 CFR 1926.95(a)
- Effective
- Not on file
- Last verified
- Nov 22, 2026
- Trades
- All trades
- Page
- Online regulation: cite by section and paragraph; there are no page numbers.
Official sourceReport a problem
- Verified for Selected Jurisdiction
29 CFR 1926.651(h): Specific excavation requirements: Protection from hazards associated with water accumulation
29 CFR 1926 · eCFR 2026-11-19
Edition and verification details
The adopted requirement and the jurisdiction were confirmed from the official sources below. Verified from the official source.
- Jurisdiction
- Federal
- Source
- Safety and Health Regulations for Construction
- Edition
- eCFR 2026-11-19
- Section
- 29 CFR 1926.651(h)
- Effective
- Not on file
- Last verified
- Nov 22, 2026
- Trades
- basements, concrete, excavation, foundations, general-contracting, landscaping, plumbing, pole-barns
- Page
- Online regulation: cite by section and paragraph; there are no page numbers.
Official sourceReport a problem
- Verified for Selected Jurisdiction
29 CFR 1926.503: Training requirements
29 CFR 1926 · eCFR 2026-11-19
Employers must train each worker who might be exposed to fall hazards, by a competent person, and keep a written certification of that training.
Edition and verification details
The adopted requirement and the jurisdiction were confirmed from the official sources below. Verified from the official source.
- Jurisdiction
- Federal
- Source
- Safety and Health Regulations for Construction
- Edition
- eCFR 2026-11-19
- Section
- 29 CFR 1926.503
- Effective
- Not on file
- Last verified
- Nov 22, 2026
- Trades
- All trades
- Page
- Online regulation: cite by section and paragraph; there are no page numbers.
Official sourceReport a problem
- Verified for Selected Jurisdiction
29 CFR 1926.850: Preparatory operations
29 CFR 1926 · eCFR 2026-11-19
Edition and verification details
The adopted requirement and the jurisdiction were confirmed from the official sources below. Verified from the official source.
- Jurisdiction
- Federal
- Source
- Safety and Health Regulations for Construction
- Edition
- eCFR 2026-11-19
- Section
- 29 CFR 1926.850
- Effective
- Not on file
- Last verified
- Nov 22, 2026
- Trades
- commercial-remodeling, demolition, general-contracting, interior-remodeling
- Page
- Online regulation: cite by section and paragraph; there are no page numbers.
Official sourceReport a problem
More federal sections
Live from the official eCFR. These haven't been reviewed by Built2Bid yet, and they set worker-safety, environmental or vehicle rules, not building code requirements.
Official eCFR · not reviewed by Built2Bid
29 CFR 1926.760: Fall protection.
OSHA construction (29 CFR 1926) › Subpart R · current text in effect since Sep 1, 2016
protected from fall hazards by guardrail systems, safety net systems, personal fall arrest systems … systems, positioning device systems or fall restraint systems. (2) Perimeter safety cables … controlled decking zones shall be protected from fall hazards as provided in paragraphs (b) and
Official eCFR · not reviewed by Built2Bid
29 CFR 1926.1423: Fall protection.
OSHA construction (29 CFR 1926) › Subpart CC · current text in effect since Sep 1, 2016
Guardrails, railings and other permanent fall protection attachments along walkways are: (A) … paint). (d) Personal fall arrest and fall restraint systems. Personal fall arrest system components … components must be used in personal fall arrest and fall restraint systems and must conform
Report a problem
Federal rules on file
Residential
EPA Lead Renovation, Repair and Painting Rule (40 CFR Part 745)
eCFR 2026-11-19
Searchable hereOfficial sourceSearch this code
Worker safety
OSHA Construction Standards (29 CFR Part 1926)
eCFR 2026-11-19
Searchable hereOfficial sourceSearch this code
OSHA Recordkeeping and Reporting (29 CFR Part 1904)
eCFR 2026-11-19
Searchable hereOfficial sourceSearch this code
Other
FMCSA Motor Carrier Safety Regulations (49 CFR)
eCFR 2026-11-19
Searchable hereOfficial sourceSearch this code
Learn it
Flashcards, quizzes and practice exams on jobsite safety, codebook navigation and running a contracting business.
How answers work
- Answers come only from official sources we have checked. We never make up code text, section numbers, page numbers or dates.
- Copyrighted model codes (like the IRC and IBC) are cited by section and linked to the official copy. We don't reproduce them.
- A statewide result is not a full local compliance check. Your city, township or county can add requirements.
Educational information only. Building codes and licensing requirements vary by jurisdiction and may change. Verify requirements with the applicable authority having jurisdiction before beginning work.