Codes & Regulations
Find the codes that apply to your project, with the source, edition and when we last checked it.
We can't give a verified answer to this yet.
Unable to verify the applicable requirement from the available official sources. Confirm with your local building department or authority having jurisdiction.
Worker safety (OSHA)
Rules that protect workers on the job. They do not replace the building code for the finished work.
- Verified for Selected Jurisdiction
29 CFR 1926.651(i): Specific excavation requirements: Stability of adjacent structures
29 CFR 1926 · eCFR 2026-11-19
Edition and verification details
The adopted requirement and the jurisdiction were confirmed from the official sources below. Verified from the official source.
- Jurisdiction
- Federal
- Source
- Safety and Health Regulations for Construction
- Edition
- eCFR 2026-11-19
- Section
- 29 CFR 1926.651(i)
- Effective
- Not on file
- Last verified
- Nov 22, 2026
- Trades
- basements, concrete, excavation, foundations, general-contracting, landscaping, plumbing, pole-barns
- Page
- Online regulation: cite by section and paragraph; there are no page numbers.
Official sourceReport a problem
- Verified for Selected Jurisdiction
29 CFR 1926.1052(a): Stairways: General
29 CFR 1926 · eCFR 2026-11-19
Construction stairways (the ones workers use during construction): landing size, a 30 to 50 degree slope, and riser heights and tread depths that are uniform within each flight, varying no more than 1/4 inch. These are worker-safety rules, not the building code rules for the finished home.
Edition and verification details
The adopted requirement and the jurisdiction were confirmed from the official sources below. Verified from the official source.
- Jurisdiction
- Federal
- Source
- Safety and Health Regulations for Construction
- Edition
- eCFR 2026-11-19
- Section
- 29 CFR 1926.1052(a)
- Effective
- Not on file
- Last verified
- Nov 22, 2026
- Trades
- All trades
- Page
- Online regulation: cite by section and paragraph; there are no page numbers.
Official sourceReport a problem
More federal sections
Live from the official eCFR. These haven't been reviewed by Built2Bid yet, and they set worker-safety, environmental or vehicle rules, not building code requirements.
Official eCFR · not reviewed by Built2Bid
29 CFR 1926.755: Column anchorage.
OSHA construction (29 CFR 1926) › Subpart R · current text in effect since Sep 1, 2016
column-to-base plate weld and the column foundation, shall be designed to resist a minimum
Official eCFR · not reviewed by Built2Bid
29 CFR 1926.305: Jacks—lever and ratchet, screw, and hydraulic.
OSHA construction (29 CFR 1926) › Subpart I · current text in effect since Sep 1, 2016
When it is necessary to provide a firm foundation, the base of the jack shall be blocked
Official eCFR · not reviewed by Built2Bid
29 CFR 1926.703: Requirements for cast-in-place concrete.
OSHA construction (29 CFR 1926) › Subpart Q · current text in effect since Sep 1, 2016
and secured when necessary, with the foundation and the form. (7) Eccentric loads on shore
Official eCFR · not reviewed by Built2Bid
29 CFR 1926.754: Structural steel assembly.
OSHA construction (29 CFR 1926) › Subpart R · current text in effect since Nov 16, 2020
unfinished bolting or welding above the foundation or uppermost permanently secured floor
Official eCFR · not reviewed by Built2Bid
49 CFR 393.5: Definitions.
FMCSA vehicles and drivers (49 CFR 350-399) › Subpart A · current text in effect since Nov 18, 2024
dwelling with or without a permanent foundation when connected to the required utilities
Official eCFR · not reviewed by Built2Bid
40 CFR 745.227: Work practice standards for conducting lead-based paint activities: target housing and child-occupied facilities.
EPA lead-safe renovation (40 CFR 745) › Subpart L · current text in effect since Dec 16, 2024
bare soil is present. (iii) Dripline/foundation areas where bare soil is present. (9) … chips on the dripline or next to the foundation below any exterior surface abated. If
Report a problem
Available Kansas codes
Kansas has no statewide building, residential, plumbing, mechanical, energy or electrical code for private construction. Cities and counties decide whether to adopt model codes by reference. The State Fire Marshal's Kansas Fire Prevention Code applies statewide, except to one- and two-family dwellings. No statewide code for most private construction; cities and counties choose and enforce their own.
Residential
EPA Lead Renovation, Repair and Painting Rule (40 CFR Part 745)
eCFR 2026-11-19
Searchable hereOfficial sourceSearch this code
Building
International Building Code
2006
Official reference availableOfficial source
Electrical
National Electrical Code (NFPA 70)
2008
Official reference availableOfficial source
Fire
International Fire Code
2006
Official reference availableOfficial source
Worker safety
OSHA Construction Standards (29 CFR Part 1926)
eCFR 2026-11-19
Searchable hereOfficial sourceSearch this code
OSHA Recordkeeping and Reporting (29 CFR Part 1904)
eCFR 2026-11-19
Searchable hereOfficial sourceSearch this code
Other
FMCSA Motor Carrier Safety Regulations (49 CFR)
eCFR 2026-11-19
Searchable hereOfficial sourceSearch this code
More sources being verified (plumbing, mechanical / fuel gas, energy). Some states leave these codes to cities and counties.
Learn it
Flashcards, quizzes and practice exams on jobsite safety, codebook navigation and running a contracting business.
How answers work
- Answers come only from official sources we have checked. We never make up code text, section numbers, page numbers or dates.
- Copyrighted model codes (like the IRC and IBC) are cited by section and linked to the official copy. We don't reproduce them.
- A statewide result is not a full local compliance check. Your city, township or county can add requirements.
Educational information only. Building codes and licensing requirements vary by jurisdiction and may change. Verify requirements with the applicable authority having jurisdiction before beginning work.