Skip to content
Built2Bid

Codes & Regulations

Find the codes that apply to your project, with the source, edition and when we last checked it.

Project location

Why we ask

Codes are adopted by the state, and cities, townships or counties can enforce or amend them. Pick the state to search statewide codes. Add the ZIP and local area to check local rules. A ZIP alone never decides who issues your permit.

Minnesota selected· Local jurisdiction not confirmedStarted from your saved Academy location.
Refine location by street address

Suggestions come from Google, and the address is checked with the U.S. Census Bureau's free lookup to find the city, township or county. We don't save it.

Quick answer

  • Statewide Source AvailableState amendment

    Minn. R. 1309.0311, subp. 3: Section R311, Means of Egress: IRC section R311.7.2, Headroom

    Minn. R. 1309 · 2020 Minnesota State Building Code

    Minnesota amends IRC R311.7.2: minimum stairway headroom is 6 feet 8 inches, with listed exceptions.

    Edition and verification details

    Verified at the state or federal level. Your local permitting office may adopt or amend it differently. Which city, county or township is the project in? Pick it under “Where is the project?” to check. The Minnesota State Building Code is the minimum standard statewide, but DLI states it is not enforceable by a municipality unless adopted by local ordinance. Confirm with the city, township or county building official for the project. Tell us where the project is

    Jurisdiction
    Minnesota
    Source
    Minnesota Rules, chapter 1309: Adoption of the International Residential Code
    Edition
    2020 Minnesota State Building Code
    Section
    Minn. R. 1309.0311, subp. 3
    Effective
    Mar 31, 2020
    Last verified
    Nov 22, 2026
    Trades
    additions, basements, decks, exterior-remodeling, framing, garages, general-contracting, interior-remodeling
    Page
    Online rule: cite by part and subpart; there are no page numbers.
    Official source
    Report a problem

Related searches

Building codes

What the adopted building, residential, electrical, mechanical or energy code requires.

  • Statewide Source AvailableState amendment

    Minn. R. 1309.0311, subp. 2: Section R311, Means of Egress: IRC section R311.7.1, Width

    Minn. R. 1309 · 2020 Minnesota State Building Code

    Minnesota replaces IRC R311.7.1: all stairways serving a dwelling or accessory structure, including exterior stairs to grade and stairs serving decks, porches and balconies, must meet the stair section, with a 36-inch minimum clear width and handrail projection limits.

    Edition and verification details

    Verified at the state or federal level. Your local permitting office may adopt or amend it differently. Which city, county or township is the project in? Pick it under “Where is the project?” to check. The Minnesota State Building Code is the minimum standard statewide, but DLI states it is not enforceable by a municipality unless adopted by local ordinance. Confirm with the city, township or county building official for the project. Tell us where the project is

    Jurisdiction
    Minnesota
    Source
    Minnesota Rules, chapter 1309: Adoption of the International Residential Code
    Edition
    2020 Minnesota State Building Code
    Section
    Minn. R. 1309.0311, subp. 2
    Effective
    Mar 31, 2020
    Last verified
    Nov 22, 2026
    Trades
    additions, basements, decks, exterior-remodeling, framing, garages, general-contracting, interior-remodeling
    Page
    Online rule: cite by part and subpart; there are no page numbers.
    Official source
    Report a problem
  • Statewide Source AvailableState amendment

    Minn. R. 1309.0311, subp. 1: Section R311, Means of Egress: IRC section R311.3.2, Floor elevations for other exterior doors

    Minn. R. 1309 · 2020 Minnesota State Building Code

    Minnesota amends IRC R311.3.2: doors other than the required egress door need a landing or floor no more than 7-3/4 inches below the threshold, with an exception for exterior stairways under 30 inches.

    Edition and verification details

    Verified at the state or federal level. Your local permitting office may adopt or amend it differently. Which city, county or township is the project in? Pick it under “Where is the project?” to check. The Minnesota State Building Code is the minimum standard statewide, but DLI states it is not enforceable by a municipality unless adopted by local ordinance. Confirm with the city, township or county building official for the project. Tell us where the project is

    Jurisdiction
    Minnesota
    Source
    Minnesota Rules, chapter 1309: Adoption of the International Residential Code
    Edition
    2020 Minnesota State Building Code
    Section
    Minn. R. 1309.0311, subp. 1
    Effective
    Mar 31, 2020
    Last verified
    Nov 22, 2026
    Trades
    additions, basements, decks, exterior-remodeling, framing, garages, general-contracting, interior-remodeling
    Page
    Online rule: cite by part and subpart; there are no page numbers.
    Official source
    Report a problem
  • Under Review

    2018 IRC Section R311.7: Stairways

    IRC · 2018

    Section title only. Read the requirement in the official source.

    Edition and verification details

    On file, but the text or how it applies here hasn't been fully verified yet. The section text has not been verified yet.

    Jurisdiction
    Minnesota
    Source
    2018 International Residential Code
    Edition
    2018
    Section
    2018 IRC Section R311.7
    Effective
    Mar 31, 2020
    Last verified
    Not verified yet
    Trades
    decks, framing, interior-remodeling, basements, additions
    Page
    Page numbers differ between print, PDF and online formats; Built2Bid cites sections only.
    Report a problem

Worker safety (OSHA)

Rules that protect workers on the job. They do not replace the building code for the finished work.

  • Under Review

    29 CFR 1926.1052(a): Stairways: General

    29 CFR 1926 · eCFR 2026-11-19

    Construction stairways (the ones workers use during construction): landing size, a 30 to 50 degree slope, and riser heights and tread depths that are uniform within each flight, varying no more than 1/4 inch. These are worker-safety rules, not the building code rules for the finished home.

    Edition and verification details

    On file, but the text or how it applies here hasn't been fully verified yet. Your state runs an OSHA-approved State Plan. Its standards govern and must be at least as effective as the federal rule shown.

    Jurisdiction
    Federal
    Source
    Safety and Health Regulations for Construction
    Edition
    eCFR 2026-11-19
    Section
    29 CFR 1926.1052(a)
    Effective
    Not on file
    Last verified
    Nov 22, 2026
    Trades
    All trades
    Page
    Online regulation: cite by section and paragraph; there are no page numbers.
    Official source
    Report a problem
  • Under Review

    29 CFR 1926.1052(b): Stairways: Temporary service

    29 CFR 1926 · eCFR 2026-11-19

    Edition and verification details

    On file, but the text or how it applies here hasn't been fully verified yet. Your state runs an OSHA-approved State Plan. Its standards govern and must be at least as effective as the federal rule shown.

    Jurisdiction
    Federal
    Source
    Safety and Health Regulations for Construction
    Edition
    eCFR 2026-11-19
    Section
    29 CFR 1926.1052(b)
    Effective
    Not on file
    Last verified
    Nov 22, 2026
    Trades
    All trades
    Page
    Online regulation: cite by section and paragraph; there are no page numbers.
    Official source
    Report a problem
  • Under Review

    29 CFR 1926.1052(c): Stairways: Stairrails and handrails

    29 CFR 1926 · eCFR 2026-11-19

    Construction stairways with four or more risers or more than 30 inches of rise need at least one handrail and stairrails on unprotected sides, with height and strength requirements.

    Edition and verification details

    On file, but the text or how it applies here hasn't been fully verified yet. Your state runs an OSHA-approved State Plan. Its standards govern and must be at least as effective as the federal rule shown.

    Jurisdiction
    Federal
    Source
    Safety and Health Regulations for Construction
    Edition
    eCFR 2026-11-19
    Section
    29 CFR 1926.1052(c)
    Effective
    Not on file
    Last verified
    Nov 22, 2026
    Trades
    All trades
    Page
    Online regulation: cite by section and paragraph; there are no page numbers.
    Official source
    Report a problem
Report a problem

Available Minnesota codes

Residential

Building

  • International Building Code

    2018 · in effect Mar 31, 2020

    Official reference availableOfficial source

  • Minnesota Rules (State Building Code)

    2020 Minnesota State Building Code · in effect Mar 31, 2020

    Searchable hereOfficial sourceSearch this code

  • Minnesota Rules (State Building Code)

    2020 Minnesota State Building Code · in effect Mar 31, 2020

    Searchable hereOfficial sourceSearch this code

Electrical

  • Minnesota Rules (State Building Code)

    2026 NEC adoption · in effect Aug 17, 2026

    Searchable hereOfficial sourceSearch this code

  • National Electrical Code (NFPA 70)

    2026 · in effect Aug 17, 2026

    Official reference availableOfficial source

  • National Electrical Code (NFPA 70)

    2023

    Official reference availableOfficial source

Mechanical / fuel gas

  • International Mechanical Code

    2018 · in effect Apr 6, 2020

    Official reference availableOfficial source

  • Minnesota Rules (State Building Code)

    2020 Minnesota State Building Code · in effect Apr 6, 2020

    Searchable hereOfficial sourceSearch this code

Energy

Worker safety

Other

More sources being verified (plumbing, fire). Some states leave these codes to cities and counties.

Learn it

Flashcards, quizzes and practice exams on jobsite safety, codebook navigation, Minnesota permits and the Minnesota Residential Code and running a contracting business.

How answers work
  • Answers come only from official sources we have checked. We never make up code text, section numbers, page numbers or dates.
  • Copyrighted model codes (like the IRC and IBC) are cited by section and linked to the official copy. We don't reproduce them.
  • A statewide result is not a full local compliance check. Your city, township or county can add requirements.

Educational information only. Building codes and licensing requirements vary by jurisdiction and may change. Verify requirements with the applicable authority having jurisdiction before beginning work.