Codes & Regulations
Find the codes that apply to your project, with the source, edition and when we last checked it.
Quick answer
- Statewide Source AvailableState amendment
Minn. R. 1309.0311, subp. 2: Section R311, Means of Egress: IRC section R311.7.1, Width
Minn. R. 1309 · 2020 Minnesota State Building Code
Minnesota replaces IRC R311.7.1: all stairways serving a dwelling or accessory structure, including exterior stairs to grade and stairs serving decks, porches and balconies, must meet the stair section, with a 36-inch minimum clear width and handrail projection limits.
Edition and verification details
Verified at the state or federal level. Your local permitting office may adopt or amend it differently. Which city, county or township is the project in? Pick it under “Where is the project?” to check. The Minnesota State Building Code is the minimum standard statewide, but DLI states it is not enforceable by a municipality unless adopted by local ordinance. Confirm with the city, township or county building official for the project. Tell us where the project is
- Jurisdiction
- Minnesota
- Source
- Minnesota Rules, chapter 1309: Adoption of the International Residential Code
- Edition
- 2020 Minnesota State Building Code
- Section
- Minn. R. 1309.0311, subp. 2
- Effective
- Mar 31, 2020
- Last verified
- Nov 22, 2026
- Trades
- additions, basements, decks, exterior-remodeling, framing, garages, general-contracting, interior-remodeling
- Page
- Online rule: cite by part and subpart; there are no page numbers.
Official sourceReport a problem
Building codes
What the adopted building, residential, electrical, mechanical or energy code requires.
- Statewide Source AvailableState amendment
Minn. R. 1309.0311, subp. 3: Section R311, Means of Egress: IRC section R311.7.2, Headroom
Minn. R. 1309 · 2020 Minnesota State Building Code
Minnesota amends IRC R311.7.2: minimum stairway headroom is 6 feet 8 inches, with listed exceptions.
Edition and verification details
Verified at the state or federal level. Your local permitting office may adopt or amend it differently. Which city, county or township is the project in? Pick it under “Where is the project?” to check. The Minnesota State Building Code is the minimum standard statewide, but DLI states it is not enforceable by a municipality unless adopted by local ordinance. Confirm with the city, township or county building official for the project. Tell us where the project is
- Jurisdiction
- Minnesota
- Source
- Minnesota Rules, chapter 1309: Adoption of the International Residential Code
- Edition
- 2020 Minnesota State Building Code
- Section
- Minn. R. 1309.0311, subp. 3
- Effective
- Mar 31, 2020
- Last verified
- Nov 22, 2026
- Trades
- additions, basements, decks, exterior-remodeling, framing, garages, general-contracting, interior-remodeling
- Page
- Online rule: cite by part and subpart; there are no page numbers.
Official sourceReport a problem
- Statewide Source AvailableState amendment
Minn. R. 1309.0311, subp. 1: Section R311, Means of Egress: IRC section R311.3.2, Floor elevations for other exterior doors
Minn. R. 1309 · 2020 Minnesota State Building Code
Minnesota amends IRC R311.3.2: doors other than the required egress door need a landing or floor no more than 7-3/4 inches below the threshold, with an exception for exterior stairways under 30 inches.
Edition and verification details
Verified at the state or federal level. Your local permitting office may adopt or amend it differently. Which city, county or township is the project in? Pick it under “Where is the project?” to check. The Minnesota State Building Code is the minimum standard statewide, but DLI states it is not enforceable by a municipality unless adopted by local ordinance. Confirm with the city, township or county building official for the project. Tell us where the project is
- Jurisdiction
- Minnesota
- Source
- Minnesota Rules, chapter 1309: Adoption of the International Residential Code
- Edition
- 2020 Minnesota State Building Code
- Section
- Minn. R. 1309.0311, subp. 1
- Effective
- Mar 31, 2020
- Last verified
- Nov 22, 2026
- Trades
- additions, basements, decks, exterior-remodeling, framing, garages, general-contracting, interior-remodeling
- Page
- Online rule: cite by part and subpart; there are no page numbers.
Official sourceReport a problem
- Under Review
2018 IRC Section R311.7: Stairways
IRC · 2018
Section title only. Read the requirement in the official source.
Edition and verification details
On file, but the text or how it applies here hasn't been fully verified yet. The section text has not been verified yet.
- Jurisdiction
- Minnesota
- Source
- 2018 International Residential Code
- Edition
- 2018
- Section
- 2018 IRC Section R311.7
- Effective
- Mar 31, 2020
- Last verified
- Not verified yet
- Trades
- decks, framing, interior-remodeling, basements, additions
- Page
- Page numbers differ between print, PDF and online formats; Built2Bid cites sections only.
Report a problem
- Statewide Source AvailableState amendment
Minn. R. 1309.0312, subp. 1: Section R312, Guards and Window Fall Protection: IRC section R312.1.1, Where required
Minn. R. 1309 · 2020 Minnesota State Building Code
Minnesota amends IRC R312.1.1: guards are required along open sides of floors, stairs, ramps and landings more than 30 inches above the floor or grade below. Insect screening is not a guard.
Edition and verification details
Verified at the state or federal level. Your local permitting office may adopt or amend it differently. Which city, county or township is the project in? Pick it under “Where is the project?” to check. The Minnesota State Building Code is the minimum standard statewide, but DLI states it is not enforceable by a municipality unless adopted by local ordinance. Confirm with the city, township or county building official for the project. Tell us where the project is
- Jurisdiction
- Minnesota
- Source
- Minnesota Rules, chapter 1309: Adoption of the International Residential Code
- Edition
- 2020 Minnesota State Building Code
- Section
- Minn. R. 1309.0312, subp. 1
- Effective
- Mar 31, 2020
- Last verified
- Nov 22, 2026
- Trades
- additions, basements, decks, exterior-remodeling, framing, garages, general-contracting, interior-remodeling, windows-doors
- Page
- Online rule: cite by part and subpart; there are no page numbers.
Official sourceReport a problem
- Statewide Source AvailableState amendment
Minn. R. 1309.0703, subp. 2b: Section R703, Exterior Covering: IRC section R703.4 Flashing
Minn. R. 1309 · 2020 Minnesota State Building Code
Edition and verification details
Verified at the state or federal level. Your local permitting office may adopt or amend it differently. Which city, county or township is the project in? Pick it under “Where is the project?” to check. The Minnesota State Building Code is the minimum standard statewide, but DLI states it is not enforceable by a municipality unless adopted by local ordinance. Confirm with the city, township or county building official for the project. Tell us where the project is
- Jurisdiction
- Minnesota
- Source
- Minnesota Rules, chapter 1309: Adoption of the International Residential Code
- Edition
- 2020 Minnesota State Building Code
- Section
- Minn. R. 1309.0703, subp. 2b
- Effective
- Mar 31, 2020
- Last verified
- Nov 22, 2026
- Trades
- exterior-remodeling, general-contracting, siding
- Page
- Online rule: cite by part and subpart; there are no page numbers.
Official sourceReport a problem
Worker safety (OSHA)
Rules that protect workers on the job. They do not replace the building code for the finished work.
- Under Review
29 CFR 1926.1052(b): Stairways: Temporary service
29 CFR 1926 · eCFR 2026-11-19
Edition and verification details
On file, but the text or how it applies here hasn't been fully verified yet. Your state runs an OSHA-approved State Plan. Its standards govern and must be at least as effective as the federal rule shown.
- Jurisdiction
- Federal
- Source
- Safety and Health Regulations for Construction
- Edition
- eCFR 2026-11-19
- Section
- 29 CFR 1926.1052(b)
- Effective
- Not on file
- Last verified
- Nov 22, 2026
- Trades
- All trades
- Page
- Online regulation: cite by section and paragraph; there are no page numbers.
Official sourceReport a problem
- Under Review
29 CFR 1926.1052(a): Stairways: General
29 CFR 1926 · eCFR 2026-11-19
Construction stairways (the ones workers use during construction): landing size, a 30 to 50 degree slope, and riser heights and tread depths that are uniform within each flight, varying no more than 1/4 inch. These are worker-safety rules, not the building code rules for the finished home.
Edition and verification details
On file, but the text or how it applies here hasn't been fully verified yet. Your state runs an OSHA-approved State Plan. Its standards govern and must be at least as effective as the federal rule shown.
- Jurisdiction
- Federal
- Source
- Safety and Health Regulations for Construction
- Edition
- eCFR 2026-11-19
- Section
- 29 CFR 1926.1052(a)
- Effective
- Not on file
- Last verified
- Nov 22, 2026
- Trades
- All trades
- Page
- Online regulation: cite by section and paragraph; there are no page numbers.
Official sourceReport a problem
- Under Review
29 CFR 1926.1052(c): Stairways: Stairrails and handrails
29 CFR 1926 · eCFR 2026-11-19
Construction stairways with four or more risers or more than 30 inches of rise need at least one handrail and stairrails on unprotected sides, with height and strength requirements.
Edition and verification details
On file, but the text or how it applies here hasn't been fully verified yet. Your state runs an OSHA-approved State Plan. Its standards govern and must be at least as effective as the federal rule shown.
- Jurisdiction
- Federal
- Source
- Safety and Health Regulations for Construction
- Edition
- eCFR 2026-11-19
- Section
- 29 CFR 1926.1052(c)
- Effective
- Not on file
- Last verified
- Nov 22, 2026
- Trades
- All trades
- Page
- Online regulation: cite by section and paragraph; there are no page numbers.
Official sourceReport a problem
Environmental rules (EPA)
Federal environmental work-practice rules.
- Local Verification Needed
40 CFR 745.82: Applicability
40 CFR 745 · eCFR 2026-11-19
The federal RRP rule applies to renovations for compensation in target housing and child-occupied facilities, except where the affected components were found free of lead-based paint by a certified inspector or risk assessor, by a certified renovator using an EPA-recognized test kit, or by an EPA-recognized lab testing paint chips (other listed exceptions apply).
Edition and verification details
Verified at the state or federal level. Your local permitting office may adopt or amend it differently. Federal rule. State programs can add to it or run their own version. Federal rule for paid renovation in pre-1978 target housing and child-occupied facilities. Some states and tribes run EPA-authorized programs with their own certification.
- Jurisdiction
- Federal
- Source
- Lead-Based Paint Poisoning Prevention in Certain Residential Structures
- Edition
- eCFR 2026-11-19
- Section
- 40 CFR 745.82
- Effective
- Not on file
- Last verified
- Nov 22, 2026
- Trades
- bathrooms, exterior-remodeling, general-contracting, handyman, interior-remodeling, kitchens, painting, siding, windows-doors
- Page
- Online regulation: cite by section and paragraph; there are no page numbers.
Official sourceReport a problem
Report a problem
Available Minnesota codes
Residential
International Residential Code
2018 · in effect Mar 31, 2020
Official reference availableOfficial source
Minnesota Rules (State Building Code)
2020 Minnesota State Building Code · in effect Mar 31, 2020
Searchable hereOfficial sourceSearch this code
EPA Lead Renovation, Repair and Painting Rule (40 CFR Part 745)
eCFR 2026-11-19
Searchable hereOfficial sourceSearch this code
Building
International Building Code
2018 · in effect Mar 31, 2020
Official reference availableOfficial source
Minnesota Rules (State Building Code)
2020 Minnesota State Building Code · in effect Mar 31, 2020
Searchable hereOfficial sourceSearch this code
Minnesota Rules (State Building Code)
2020 Minnesota State Building Code · in effect Mar 31, 2020
Searchable hereOfficial sourceSearch this code
Electrical
Minnesota Rules (State Building Code)
2026 NEC adoption · in effect Aug 17, 2026
Searchable hereOfficial sourceSearch this code
National Electrical Code (NFPA 70)
2026 · in effect Aug 17, 2026
Official reference availableOfficial source
National Electrical Code (NFPA 70)
2023
Official reference availableOfficial source
Mechanical / fuel gas
International Mechanical Code
2018 · in effect Apr 6, 2020
Official reference availableOfficial source
Minnesota Rules (State Building Code)
2020 Minnesota State Building Code · in effect Apr 6, 2020
Searchable hereOfficial sourceSearch this code
Energy
International Energy Conservation Code
2012
Official reference availableOfficial source
Minnesota Rules (State Building Code)
2015 residential energy code (2012 IECC)
Searchable hereOfficial sourceSearch this code
Worker safety
OSHA Construction Standards (29 CFR Part 1926)
eCFR 2026-11-19
Searchable hereOfficial sourceSearch this code
OSHA Recordkeeping and Reporting (29 CFR Part 1904)
eCFR 2026-11-19
Searchable hereOfficial sourceSearch this code
OSHA-approved State Plan
eCFR 2026-11-19
Searchable hereOfficial sourceSearch this code
Other
FMCSA Motor Carrier Safety Regulations (49 CFR)
eCFR 2026-11-19
Searchable hereOfficial sourceSearch this code
More sources being verified (plumbing, fire). Some states leave these codes to cities and counties.
Learn it
Flashcards, quizzes and practice exams on jobsite safety, codebook navigation, Minnesota permits and the Minnesota Residential Code and running a contracting business.
How answers work
- Answers come only from official sources we have checked. We never make up code text, section numbers, page numbers or dates.
- Copyrighted model codes (like the IRC and IBC) are cited by section and linked to the official copy. We don't reproduce them.
- A statewide result is not a full local compliance check. Your city, township or county can add requirements.
Educational information only. Building codes and licensing requirements vary by jurisdiction and may change. Verify requirements with the applicable authority having jurisdiction before beginning work.