Skip to content
Built2Bid

Codes & Regulations

Find the codes that apply to your project, with the source, edition and when we last checked it.

Project location

Why we ask

Codes are adopted by the state, and cities, townships or counties can enforce or amend them. Pick the state to search statewide codes. Add the ZIP and local area to check local rules. A ZIP alone never decides who issues your permit.

Federal rules
Refine location by street address

Suggestions come from Google, and the address is checked with the U.S. Census Bureau's free lookup to find the city, township or county. We don't save it.

Quick answer

  • Verified for Selected Jurisdiction

    29 CFR 1926.1052(c): Stairways: Stairrails and handrails

    29 CFR 1926 · eCFR 2026-11-19

    Construction stairways with four or more risers or more than 30 inches of rise need at least one handrail and stairrails on unprotected sides, with height and strength requirements.

    Edition and verification details

    The adopted requirement and the jurisdiction were confirmed from the official sources below. Verified from the official source.

    Jurisdiction
    Federal
    Source
    Safety and Health Regulations for Construction
    Edition
    eCFR 2026-11-19
    Section
    29 CFR 1926.1052(c)
    Effective
    Not on file
    Last verified
    Nov 22, 2026
    Trades
    All trades
    Page
    Online regulation: cite by section and paragraph; there are no page numbers.
    Official source
    Report a problem

Related searches

Building codes

What the adopted building, residential, electrical, mechanical or energy code requires.

  • Local Verification NeededState amendment

    Minn. R. 1309.0311, subp. 2: Section R311, Means of Egress: IRC section R311.7.1, Width

    Minn. R. 1309 · 2020 Minnesota State Building Code

    Minnesota replaces IRC R311.7.1: all stairways serving a dwelling or accessory structure, including exterior stairs to grade and stairs serving decks, porches and balconies, must meet the stair section, with a 36-inch minimum clear width and handrail projection limits.

    Edition and verification details

    Verified at the state or federal level. Your local permitting office may adopt or amend it differently. Choose a state to check applicability.

    Jurisdiction
    Minnesota
    Source
    Minnesota Rules, chapter 1309: Adoption of the International Residential Code
    Edition
    2020 Minnesota State Building Code
    Section
    Minn. R. 1309.0311, subp. 2
    Effective
    Not on file
    Last verified
    Nov 22, 2026
    Trades
    additions, basements, decks, exterior-remodeling, framing, garages, general-contracting, interior-remodeling
    Page
    Online rule: cite by part and subpart; there are no page numbers.
    Official source
    Report a problem
  • Under Review

    2018 IRC Section R311.7: Stairways

    IRC · 2018

    Section title only. Read the requirement in the official source.

    Edition and verification details

    Verified at the state or federal level. Your local permitting office may adopt or amend it differently. Choose a state to check applicability.

    Jurisdiction
    Model code (applies only where adopted)
    Source
    2018 International Residential Code
    Edition
    2018
    Section
    2018 IRC Section R311.7
    Effective
    Not on file
    Last verified
    Not verified yet
    Trades
    decks, framing, interior-remodeling, basements, additions
    Page
    Page numbers differ between print, PDF and online formats; Built2Bid cites sections only.
    Report a problem
  • Local Verification NeededState amendment

    Minn. R. 1309.0311, subp. 1: Section R311, Means of Egress: IRC section R311.3.2, Floor elevations for other exterior doors

    Minn. R. 1309 · 2020 Minnesota State Building Code

    Minnesota amends IRC R311.3.2: doors other than the required egress door need a landing or floor no more than 7-3/4 inches below the threshold, with an exception for exterior stairways under 30 inches.

    Edition and verification details

    Verified at the state or federal level. Your local permitting office may adopt or amend it differently. Choose a state to check applicability.

    Jurisdiction
    Minnesota
    Source
    Minnesota Rules, chapter 1309: Adoption of the International Residential Code
    Edition
    2020 Minnesota State Building Code
    Section
    Minn. R. 1309.0311, subp. 1
    Effective
    Not on file
    Last verified
    Nov 22, 2026
    Trades
    additions, basements, decks, exterior-remodeling, framing, garages, general-contracting, interior-remodeling
    Page
    Online rule: cite by part and subpart; there are no page numbers.
    Official source
    Report a problem
  • Local Verification NeededState amendment

    Minn. R. 1309.0311, subp. 3: Section R311, Means of Egress: IRC section R311.7.2, Headroom

    Minn. R. 1309 · 2020 Minnesota State Building Code

    Minnesota amends IRC R311.7.2: minimum stairway headroom is 6 feet 8 inches, with listed exceptions.

    Edition and verification details

    Verified at the state or federal level. Your local permitting office may adopt or amend it differently. Choose a state to check applicability.

    Jurisdiction
    Minnesota
    Source
    Minnesota Rules, chapter 1309: Adoption of the International Residential Code
    Edition
    2020 Minnesota State Building Code
    Section
    Minn. R. 1309.0311, subp. 3
    Effective
    Not on file
    Last verified
    Nov 22, 2026
    Trades
    additions, basements, decks, exterior-remodeling, framing, garages, general-contracting, interior-remodeling
    Page
    Online rule: cite by part and subpart; there are no page numbers.
    Official source
    Report a problem

Worker safety (OSHA)

Rules that protect workers on the job. They do not replace the building code for the finished work.

  • Verified for Selected Jurisdiction

    29 CFR 1926.1052(a): Stairways: General

    29 CFR 1926 · eCFR 2026-11-19

    Construction stairways (the ones workers use during construction): landing size, a 30 to 50 degree slope, and riser heights and tread depths that are uniform within each flight, varying no more than 1/4 inch. These are worker-safety rules, not the building code rules for the finished home.

    Edition and verification details

    The adopted requirement and the jurisdiction were confirmed from the official sources below. Verified from the official source.

    Jurisdiction
    Federal
    Source
    Safety and Health Regulations for Construction
    Edition
    eCFR 2026-11-19
    Section
    29 CFR 1926.1052(a)
    Effective
    Not on file
    Last verified
    Nov 22, 2026
    Trades
    All trades
    Page
    Online regulation: cite by section and paragraph; there are no page numbers.
    Official source
    Report a problem
  • Verified for Selected Jurisdiction

    29 CFR 1926.1052(b): Stairways: Temporary service

    29 CFR 1926 · eCFR 2026-11-19

    Edition and verification details

    The adopted requirement and the jurisdiction were confirmed from the official sources below. Verified from the official source.

    Jurisdiction
    Federal
    Source
    Safety and Health Regulations for Construction
    Edition
    eCFR 2026-11-19
    Section
    29 CFR 1926.1052(b)
    Effective
    Not on file
    Last verified
    Nov 22, 2026
    Trades
    All trades
    Page
    Online regulation: cite by section and paragraph; there are no page numbers.
    Official source
    Report a problem

More federal sections

Live from the official eCFR. These haven't been reviewed by Built2Bid yet, and they set worker-safety, environmental or vehicle rules, not building code requirements.

  • Official eCFR · not reviewed by Built2Bid

    29 CFR 1926.1050: Scope, application, and definitions applicable to this subpart.

    OSHA construction (29 CFR 1926) › Subpart X · current text in effect since Sep 1, 2016

    rails of the ladder to reach the landing. Handrail means a rail used to provide employees … form of stairs. The assenbly may include handrails. Lower levels means those areas to which … surface of a stairrail system may also be a “handrail.” Step stool (ladder type) means a self-supporting

    Read it on eCFRSee it in the codebook

  • Official eCFR · not reviewed by Built2Bid

    29 CFR 1926.451: General requirements.

    OSHA construction (29 CFR 1926) › Subpart L · current text in effect since Sep 1, 2016

    serving as a handrail, unless a separate handrail is provided. (iii) Handrails, and toprails … toprails that serve as handrails, shall provide an adequate handhold for employees grasping … avoid falling. (iv) Stairrail systems and handrails shall be surfaced to prevent injury to

    Read it on eCFRSee it in the codebook

  • Official eCFR · not reviewed by Built2Bid

    29 CFR 1926.750: Scope.

    OSHA construction (29 CFR 1926) › Subpart R · current text in effect since Sep 1, 2016

    metals and metal work; ladders; railings; handrails; fences and gates; gratings; trench covers;

    Read it on eCFRSee it in the codebook

  • Official eCFR · not reviewed by Built2Bid

    29 CFR 1926.1412: Inspections.

    OSHA construction (29 CFR 1926) › Subpart CC · current text in effect since Sep 1, 2016

    steps, ladders, handrails, guards: Missing. (xxi) Steps, ladders, handrails, guards: In unusable/unsafe

    Read it on eCFRSee it in the codebook

  • Official eCFR · not reviewed by Built2Bid

    40 CFR 745.83: Definitions.

    EPA lead-safe renovation (40 CFR 745) › Subpart E · current text in effect since Nov 12, 2024

    work, railings and railing caps, siding, handrails, stair risers and treads, stair stringers

    Read it on eCFRSee it in the codebook

  • Official eCFR · not reviewed by Built2Bid

    29 CFR 1926.500: Scope, application, and definitions applicable to this subpart.

    OSHA construction (29 CFR 1926) › Subpart M · current text in effect since Sep 1, 2016

    for stairways, stairrail systems, and handrails are provided in subpart X of this part

    Read it on eCFRSee it in the codebook

Report a problem

Federal rules on file

Residential

Worker safety

Other

Learn it

Flashcards, quizzes and practice exams on jobsite safety, codebook navigation and running a contracting business.

How answers work
  • Answers come only from official sources we have checked. We never make up code text, section numbers, page numbers or dates.
  • Copyrighted model codes (like the IRC and IBC) are cited by section and linked to the official copy. We don't reproduce them.
  • A statewide result is not a full local compliance check. Your city, township or county can add requirements.

Educational information only. Building codes and licensing requirements vary by jurisdiction and may change. Verify requirements with the applicable authority having jurisdiction before beginning work.