Codes & Regulations
Find the codes that apply to your project, with the source, edition and when we last checked it.
We can't give a verified answer to this yet.
Unable to verify the applicable requirement from the available official sources. Confirm with your local building department or authority having jurisdiction.
Related searches
- ladder · try fall protection
Building codes
What the adopted building, residential, electrical, mechanical or energy code requires.
- Statewide Source AvailableState amendment
Minn. R. 1309.0311, subp. 3: Section R311, Means of Egress: IRC section R311.7.2, Headroom
Minn. R. 1309 · 2020 Minnesota State Building Code
Minnesota amends IRC R311.7.2: minimum stairway headroom is 6 feet 8 inches, with listed exceptions.
Edition and verification details
Verified at the state or federal level. Your local permitting office may adopt or amend it differently. Which city, county or township is the project in? Pick it under “Where is the project?” to check. The Minnesota State Building Code is the minimum standard statewide, but DLI states it is not enforceable by a municipality unless adopted by local ordinance. Confirm with the city, township or county building official for the project. Tell us where the project is
- Jurisdiction
- Minnesota
- Source
- Minnesota Rules, chapter 1309: Adoption of the International Residential Code
- Edition
- 2020 Minnesota State Building Code
- Section
- Minn. R. 1309.0311, subp. 3
- Effective
- Mar 31, 2020
- Last verified
- Nov 22, 2026
- Trades
- additions, basements, decks, exterior-remodeling, framing, garages, general-contracting, interior-remodeling
- Page
- Online rule: cite by part and subpart; there are no page numbers.
Official sourceReport a problem
- Statewide Source AvailableState amendment
Minn. R. 1309.0703, subp. 3: Section R703, Exterior Covering: IRC Section R703.7
Minn. R. 1309 · 2020 Minnesota State Building Code
Edition and verification details
Verified at the state or federal level. Your local permitting office may adopt or amend it differently. Which city, county or township is the project in? Pick it under “Where is the project?” to check. The Minnesota State Building Code is the minimum standard statewide, but DLI states it is not enforceable by a municipality unless adopted by local ordinance. Confirm with the city, township or county building official for the project. Tell us where the project is
- Jurisdiction
- Minnesota
- Source
- Minnesota Rules, chapter 1309: Adoption of the International Residential Code
- Edition
- 2020 Minnesota State Building Code
- Section
- Minn. R. 1309.0703, subp. 3
- Effective
- Mar 31, 2020
- Last verified
- Nov 22, 2026
- Trades
- exterior-remodeling, general-contracting, siding
- Page
- Online rule: cite by part and subpart; there are no page numbers.
Official sourceReport a problem
- Statewide Source AvailableState amendment
Minn. R. 1309.0507, subp. 3: Section R507, Exterior Decks: IRC Table R507.6
Minn. R. 1309 · 2020 Minnesota State Building Code
Edition and verification details
Verified at the state or federal level. Your local permitting office may adopt or amend it differently. Which city, county or township is the project in? Pick it under “Where is the project?” to check. The Minnesota State Building Code is the minimum standard statewide, but DLI states it is not enforceable by a municipality unless adopted by local ordinance. Confirm with the city, township or county building official for the project. Tell us where the project is
- Jurisdiction
- Minnesota
- Source
- Minnesota Rules, chapter 1309: Adoption of the International Residential Code
- Edition
- 2020 Minnesota State Building Code
- Section
- Minn. R. 1309.0507, subp. 3
- Effective
- Mar 31, 2020
- Last verified
- Nov 22, 2026
- Trades
- decks, general-contracting
- Page
- Online rule: cite by part and subpart; there are no page numbers.
Official sourceReport a problem
- Statewide Source AvailableState amendment
Minn. R. 1309.0403, subp. 2: Section R403, Footings: IRC section R403.1.6
Minn. R. 1309 · 2020 Minnesota State Building Code
Minnesota amends IRC R403.1.6 (foundation anchorage): anchor bolt size, spacing and placement for sill and sole plates.
Edition and verification details
Verified at the state or federal level. Your local permitting office may adopt or amend it differently. Which city, county or township is the project in? Pick it under “Where is the project?” to check. The Minnesota State Building Code is the minimum standard statewide, but DLI states it is not enforceable by a municipality unless adopted by local ordinance. Confirm with the city, township or county building official for the project. Tell us where the project is
- Jurisdiction
- Minnesota
- Source
- Minnesota Rules, chapter 1309: Adoption of the International Residential Code
- Edition
- 2020 Minnesota State Building Code
- Section
- Minn. R. 1309.0403, subp. 2
- Effective
- Mar 31, 2020
- Last verified
- Nov 22, 2026
- Trades
- additions, concrete, decks, foundations, garages, general-contracting, pole-barns
- Page
- Online rule: cite by part and subpart; there are no page numbers.
Official sourceReport a problem
- Statewide Source AvailableState amendment
Minn. R. 1309.0703, subp. 2b: Section R703, Exterior Covering: IRC section R703.4 Flashing
Minn. R. 1309 · 2020 Minnesota State Building Code
Edition and verification details
Verified at the state or federal level. Your local permitting office may adopt or amend it differently. Which city, county or township is the project in? Pick it under “Where is the project?” to check. The Minnesota State Building Code is the minimum standard statewide, but DLI states it is not enforceable by a municipality unless adopted by local ordinance. Confirm with the city, township or county building official for the project. Tell us where the project is
- Jurisdiction
- Minnesota
- Source
- Minnesota Rules, chapter 1309: Adoption of the International Residential Code
- Edition
- 2020 Minnesota State Building Code
- Section
- Minn. R. 1309.0703, subp. 2b
- Effective
- Mar 31, 2020
- Last verified
- Nov 22, 2026
- Trades
- exterior-remodeling, general-contracting, siding
- Page
- Online rule: cite by part and subpart; there are no page numbers.
Official sourceReport a problem
- Statewide Source AvailableState amendment
Minn. R. 1309.0403, subp. 1: Section R403, Footings: IRC section R403.1.4.1
Minn. R. 1309 · 2020 Minnesota State Building Code
Minnesota amends IRC R403.1.4.1 (frost protection): footings can't bear on frozen soil, and permanent supports must be protected from frost by one of the listed methods.
Edition and verification details
Verified at the state or federal level. Your local permitting office may adopt or amend it differently. Which city, county or township is the project in? Pick it under “Where is the project?” to check. The Minnesota State Building Code is the minimum standard statewide, but DLI states it is not enforceable by a municipality unless adopted by local ordinance. Confirm with the city, township or county building official for the project. Tell us where the project is
- Jurisdiction
- Minnesota
- Source
- Minnesota Rules, chapter 1309: Adoption of the International Residential Code
- Edition
- 2020 Minnesota State Building Code
- Section
- Minn. R. 1309.0403, subp. 1
- Effective
- Mar 31, 2020
- Last verified
- Nov 22, 2026
- Trades
- additions, concrete, decks, foundations, garages, general-contracting, pole-barns
- Page
- Online rule: cite by part and subpart; there are no page numbers.
Official sourceReport a problem
- Statewide Source AvailableState amendment
Minn. R. 1309.0312, subp. 2: Section R312, Guards and Window Fall Protection: IRC section R312.2, Window fall protection
Minn. R. 1309 · 2020 Minnesota State Building Code
Minnesota amends the IRC window fall protection section (R312.2).
Edition and verification details
Verified at the state or federal level. Your local permitting office may adopt or amend it differently. Which city, county or township is the project in? Pick it under “Where is the project?” to check. The Minnesota State Building Code is the minimum standard statewide, but DLI states it is not enforceable by a municipality unless adopted by local ordinance. Confirm with the city, township or county building official for the project. Tell us where the project is
- Jurisdiction
- Minnesota
- Source
- Minnesota Rules, chapter 1309: Adoption of the International Residential Code
- Edition
- 2020 Minnesota State Building Code
- Section
- Minn. R. 1309.0312, subp. 2
- Effective
- Mar 31, 2020
- Last verified
- Nov 22, 2026
- Trades
- additions, basements, decks, exterior-remodeling, framing, garages, general-contracting, interior-remodeling, windows-doors
- Page
- Online rule: cite by part and subpart; there are no page numbers.
Official sourceReport a problem
- Statewide Source AvailableState amendment
Minn. R. 1309.0507, subp. 1: Section R507, Exterior Decks: IRC Table R507.3.1
Minn. R. 1309 · 2020 Minnesota State Building Code
Minnesota replaces IRC Table R507.3.1 (minimum deck footing size by soil bearing value, live load and tributary area). The table doesn't display well as text here: open the official source.
Edition and verification details
Verified at the state or federal level. Your local permitting office may adopt or amend it differently. Which city, county or township is the project in? Pick it under “Where is the project?” to check. The Minnesota State Building Code is the minimum standard statewide, but DLI states it is not enforceable by a municipality unless adopted by local ordinance. Confirm with the city, township or county building official for the project. Tell us where the project is
- Jurisdiction
- Minnesota
- Source
- Minnesota Rules, chapter 1309: Adoption of the International Residential Code
- Edition
- 2020 Minnesota State Building Code
- Section
- Minn. R. 1309.0507, subp. 1
- Effective
- Mar 31, 2020
- Last verified
- Nov 22, 2026
- Trades
- decks, general-contracting
- Page
- Online rule: cite by part and subpart; there are no page numbers.
Official sourceReport a problem
- Statewide Source AvailableState amendment
Minn. R. 1309.0507, subp. 4: Section R507, Exterior Decks: IRC Table 507.9.1.3(1)
Minn. R. 1309 · 2020 Minnesota State Building Code
Minnesota replaces IRC Table R507.9.1.3(1) (deck ledger connection). Open the official source to read the table.
Edition and verification details
Verified at the state or federal level. Your local permitting office may adopt or amend it differently. Which city, county or township is the project in? Pick it under “Where is the project?” to check. The Minnesota State Building Code is the minimum standard statewide, but DLI states it is not enforceable by a municipality unless adopted by local ordinance. Confirm with the city, township or county building official for the project. Tell us where the project is
- Jurisdiction
- Minnesota
- Source
- Minnesota Rules, chapter 1309: Adoption of the International Residential Code
- Edition
- 2020 Minnesota State Building Code
- Section
- Minn. R. 1309.0507, subp. 4
- Effective
- Mar 31, 2020
- Last verified
- Nov 22, 2026
- Trades
- decks, general-contracting
- Page
- Online rule: cite by part and subpart; there are no page numbers.
Official sourceReport a problem
Adoption and administration
Which edition applies, when it took effect and who enforces it.
- Statewide Source Available
Minn. R. 1300.0120, subp. 3: Permits: Annual permit records
Minn. R. 1300 · 2020 Minnesota State Building Code
Edition and verification details
Verified at the state or federal level. Your local permitting office may adopt or amend it differently. Which city, county or township is the project in? Pick it under “Where is the project?” to check. The Minnesota State Building Code is the minimum standard statewide, but DLI states it is not enforceable by a municipality unless adopted by local ordinance. Confirm with the city, township or county building official for the project. Tell us where the project is
- Jurisdiction
- Minnesota
- Source
- Minnesota Rules, chapter 1300: Minnesota Building Code administration
- Edition
- 2020 Minnesota State Building Code
- Section
- Minn. R. 1300.0120, subp. 3
- Effective
- Mar 31, 2020
- Last verified
- Nov 22, 2026
- Trades
- All trades
- Page
- Online rule: cite by part and subpart; there are no page numbers.
Official sourceReport a problem
- Statewide Source Available
Minn. R. 1309.0010, subp. 3: Adoption of International Residential Code (IRC) by Reference: Replacement chapters
Minn. R. 1309 · 2020 Minnesota State Building Code
Minnesota deletes and replaces several IRC chapters: administration (ch. 1), energy (ch. 11), mechanical (ch. 12 to 24), plumbing (ch. 25 to 33, except P2904) and electrical (ch. 34 to 43, except R314 and R315).
Edition and verification details
Verified at the state or federal level. Your local permitting office may adopt or amend it differently. Which city, county or township is the project in? Pick it under “Where is the project?” to check. The Minnesota State Building Code is the minimum standard statewide, but DLI states it is not enforceable by a municipality unless adopted by local ordinance. Confirm with the city, township or county building official for the project. Tell us where the project is
- Jurisdiction
- Minnesota
- Source
- Minnesota Rules, chapter 1309: Adoption of the International Residential Code
- Edition
- 2020 Minnesota State Building Code
- Section
- Minn. R. 1309.0010, subp. 3
- Effective
- Mar 31, 2020
- Last verified
- Nov 22, 2026
- Trades
- All trades
- Page
- Online rule: cite by part and subpart; there are no page numbers.
Official sourceReport a problem
- Statewide Source Available
Minn. R. 1322.0010, subp. 3: Adoption of International Energy Conservation Code (IECC) by Reference: Replacement chapters
Minn. R. 1322 · 2015 residential energy code (2012 IECC)
Edition and verification details
Verified at the state or federal level. Your local permitting office may adopt or amend it differently. Which city, county or township is the project in? Pick it under “Where is the project?” to check. The Minnesota State Building Code is the minimum standard statewide, but DLI states it is not enforceable by a municipality unless adopted by local ordinance. Confirm with the city, township or county building official for the project. Tell us where the project is
- Jurisdiction
- Minnesota
- Source
- Minnesota Rules, chapter 1322: Minnesota Residential Energy Code
- Edition
- 2015 residential energy code (2012 IECC)
- Section
- Minn. R. 1322.0010, subp. 3
- Effective
- Not on file
- Last verified
- Nov 22, 2026
- Trades
- general-contracting, hvac, insulation, windows-doors
- Page
- Online rule: cite by part and subpart; there are no page numbers.
Official sourceReport a problem
- Statewide Source Available
Minn. R. 1300.0120, subp. 4: Permits: Work exempt from permit
Minn. R. 1300 · 2020 Minnesota State Building Code
Lists work exempt from a building permit in Minnesota, for example one-story detached accessory structures up to 200 square feet, fences up to 7 feet high, and decks or platforms no more than 30 inches above grade that aren't attached to a structure with frost footings and aren't part of an accessible route. Exempt work must still meet the code.
Edition and verification details
Verified at the state or federal level. Your local permitting office may adopt or amend it differently. Which city, county or township is the project in? Pick it under “Where is the project?” to check. The Minnesota State Building Code is the minimum standard statewide, but DLI states it is not enforceable by a municipality unless adopted by local ordinance. Confirm with the city, township or county building official for the project. Tell us where the project is
- Jurisdiction
- Minnesota
- Source
- Minnesota Rules, chapter 1300: Minnesota Building Code administration
- Edition
- 2020 Minnesota State Building Code
- Section
- Minn. R. 1300.0120, subp. 4
- Effective
- Mar 31, 2020
- Last verified
- Nov 22, 2026
- Trades
- All trades
- Page
- Online rule: cite by part and subpart; there are no page numbers.
Official sourceReport a problem
Worker safety (OSHA)
Rules that protect workers on the job. They do not replace the building code for the finished work.
- Under Review
29 CFR 1926.1053(b): Ladders: Use
29 CFR 1926 · eCFR 2026-11-19
Ladder use: when a portable ladder is used to reach an upper landing, its side rails must extend at least 3 feet above the landing, or the ladder must be secured at the top with a grab device. Other rules cover loads, angles, footing and inspection.
Edition and verification details
On file, but the text or how it applies here hasn't been fully verified yet. Your state runs an OSHA-approved State Plan. Its standards govern and must be at least as effective as the federal rule shown.
- Jurisdiction
- Federal
- Source
- Safety and Health Regulations for Construction
- Edition
- eCFR 2026-11-19
- Section
- 29 CFR 1926.1053(b)
- Effective
- Not on file
- Last verified
- Nov 22, 2026
- Trades
- All trades
- Page
- Online regulation: cite by section and paragraph; there are no page numbers.
Official sourceReport a problem
- Under Review
29 CFR 1926.1053(a): Ladders: General
29 CFR 1926 · eCFR 2026-11-19
Ladder construction: load capacities, rung spacing and other design requirements for portable, fixed and job-made ladders.
Edition and verification details
On file, but the text or how it applies here hasn't been fully verified yet. Your state runs an OSHA-approved State Plan. Its standards govern and must be at least as effective as the federal rule shown.
- Jurisdiction
- Federal
- Source
- Safety and Health Regulations for Construction
- Edition
- eCFR 2026-11-19
- Section
- 29 CFR 1926.1053(a)
- Effective
- Not on file
- Last verified
- Nov 22, 2026
- Trades
- All trades
- Page
- Online regulation: cite by section and paragraph; there are no page numbers.
Official sourceReport a problem
- Under Review
29 CFR 1926.451(g): General requirements: Fall protection
29 CFR 1926 · eCFR 2026-11-19
Workers on a scaffold more than 10 feet above a lower level must be protected from falling, with the type of protection depending on the scaffold.
Edition and verification details
On file, but the text or how it applies here hasn't been fully verified yet. Your state runs an OSHA-approved State Plan. Its standards govern and must be at least as effective as the federal rule shown.
- Jurisdiction
- Federal
- Source
- Safety and Health Regulations for Construction
- Edition
- eCFR 2026-11-19
- Section
- 29 CFR 1926.451(g)
- Effective
- Not on file
- Last verified
- Nov 22, 2026
- Trades
- general-contracting, masonry, painting, pressure-washing, roofing, siding, soft-washing
- Page
- Online regulation: cite by section and paragraph; there are no page numbers.
Official sourceReport a problem
- Under Review
29 CFR 1926.502(d): Fall protection systems criteria and practices: Personal fall arrest systems
29 CFR 1926 · eCFR 2026-11-19
Personal fall arrest systems: anchorages, connectors, harnesses and lanyards must meet strength and use requirements, and the system must limit free fall and arrest forces.
Edition and verification details
On file, but the text or how it applies here hasn't been fully verified yet. Your state runs an OSHA-approved State Plan. Its standards govern and must be at least as effective as the federal rule shown.
- Jurisdiction
- Federal
- Source
- Safety and Health Regulations for Construction
- Edition
- eCFR 2026-11-19
- Section
- 29 CFR 1926.502(d)
- Effective
- Not on file
- Last verified
- Nov 22, 2026
- Trades
- All trades
- Page
- Online regulation: cite by section and paragraph; there are no page numbers.
Official sourceReport a problem
- Under Review
29 CFR 1926.501(b): Duty to have fall protection: paragraph (b)
29 CFR 1926 · eCFR 2026-11-19
Employers must protect workers from falls of 6 feet or more to a lower level, using guardrails, safety nets or personal fall arrest systems, with specific options for leading edges, holes, low-slope and steep roofs, and residential construction (where a written fall protection plan is allowed only when the employer can show the usual systems are infeasible or more hazardous).
Edition and verification details
On file, but the text or how it applies here hasn't been fully verified yet. Your state runs an OSHA-approved State Plan. Its standards govern and must be at least as effective as the federal rule shown.
- Jurisdiction
- Federal
- Source
- Safety and Health Regulations for Construction
- Edition
- eCFR 2026-11-19
- Section
- 29 CFR 1926.501(b)
- Effective
- Not on file
- Last verified
- Nov 22, 2026
- Trades
- All trades
- Page
- Online regulation: cite by section and paragraph; there are no page numbers.
Official sourceReport a problem
- Under Review
29 CFR 1926.502(b): Fall protection systems criteria and practices: Guardrail systems
29 CFR 1926 · eCFR 2026-11-19
Guardrail systems: the top edge of the top rail must be 42 inches, plus or minus 3 inches, above the walking/working level, with midrails or equivalent and strength requirements.
Edition and verification details
On file, but the text or how it applies here hasn't been fully verified yet. Your state runs an OSHA-approved State Plan. Its standards govern and must be at least as effective as the federal rule shown.
- Jurisdiction
- Federal
- Source
- Safety and Health Regulations for Construction
- Edition
- eCFR 2026-11-19
- Section
- 29 CFR 1926.502(b)
- Effective
- Not on file
- Last verified
- Nov 22, 2026
- Trades
- All trades
- Page
- Online regulation: cite by section and paragraph; there are no page numbers.
Official sourceReport a problem
- Under Review
29 CFR 1926.1052(a): Stairways: General
29 CFR 1926 · eCFR 2026-11-19
Construction stairways (the ones workers use during construction): landing size, a 30 to 50 degree slope, and riser heights and tread depths that are uniform within each flight, varying no more than 1/4 inch. These are worker-safety rules, not the building code rules for the finished home.
Edition and verification details
On file, but the text or how it applies here hasn't been fully verified yet. Your state runs an OSHA-approved State Plan. Its standards govern and must be at least as effective as the federal rule shown.
- Jurisdiction
- Federal
- Source
- Safety and Health Regulations for Construction
- Edition
- eCFR 2026-11-19
- Section
- 29 CFR 1926.1052(a)
- Effective
- Not on file
- Last verified
- Nov 22, 2026
- Trades
- All trades
- Page
- Online regulation: cite by section and paragraph; there are no page numbers.
Official sourceReport a problem
- Under Review
29 CFR 1926.1060: Training requirements
29 CFR 1926 · eCFR 2026-11-19
Edition and verification details
On file, but the text or how it applies here hasn't been fully verified yet. Your state runs an OSHA-approved State Plan. Its standards govern and must be at least as effective as the federal rule shown.
- Jurisdiction
- Federal
- Source
- Safety and Health Regulations for Construction
- Edition
- eCFR 2026-11-19
- Section
- 29 CFR 1926.1060
- Effective
- Not on file
- Last verified
- Nov 22, 2026
- Trades
- All trades
- Page
- Online regulation: cite by section and paragraph; there are no page numbers.
Official sourceReport a problem
- Under Review
29 CFR 1926.651(c): Specific excavation requirements: Access and egress
29 CFR 1926 · eCFR 2026-11-19
Edition and verification details
On file, but the text or how it applies here hasn't been fully verified yet. Your state runs an OSHA-approved State Plan. Its standards govern and must be at least as effective as the federal rule shown.
- Jurisdiction
- Federal
- Source
- Safety and Health Regulations for Construction
- Edition
- eCFR 2026-11-19
- Section
- 29 CFR 1926.651(c)
- Effective
- Not on file
- Last verified
- Nov 22, 2026
- Trades
- basements, concrete, excavation, foundations, general-contracting, landscaping, plumbing, pole-barns
- Page
- Online regulation: cite by section and paragraph; there are no page numbers.
Official sourceReport a problem
- Under Review
29 CFR 1926.652(a): Requirements for protective systems: Protection of employees in excavations
29 CFR 1926 · eCFR 2026-11-19
Workers in an excavation must be protected from cave-ins by an adequate protective system unless the excavation is entirely in stable rock, or is less than 5 feet deep and a competent person finds no indication of a potential cave-in.
Edition and verification details
On file, but the text or how it applies here hasn't been fully verified yet. Your state runs an OSHA-approved State Plan. Its standards govern and must be at least as effective as the federal rule shown.
- Jurisdiction
- Federal
- Source
- Safety and Health Regulations for Construction
- Edition
- eCFR 2026-11-19
- Section
- 29 CFR 1926.652(a)
- Effective
- Not on file
- Last verified
- Nov 22, 2026
- Trades
- basements, concrete, excavation, foundations, general-contracting, plumbing
- Page
- Online regulation: cite by section and paragraph; there are no page numbers.
Official sourceReport a problem
- Under Review
29 CFR 1926.1052(c): Stairways: Stairrails and handrails
29 CFR 1926 · eCFR 2026-11-19
Construction stairways with four or more risers or more than 30 inches of rise need at least one handrail and stairrails on unprotected sides, with height and strength requirements.
Edition and verification details
On file, but the text or how it applies here hasn't been fully verified yet. Your state runs an OSHA-approved State Plan. Its standards govern and must be at least as effective as the federal rule shown.
- Jurisdiction
- Federal
- Source
- Safety and Health Regulations for Construction
- Edition
- eCFR 2026-11-19
- Section
- 29 CFR 1926.1052(c)
- Effective
- Not on file
- Last verified
- Nov 22, 2026
- Trades
- All trades
- Page
- Online regulation: cite by section and paragraph; there are no page numbers.
Official sourceReport a problem
Environmental rules (EPA)
Federal environmental work-practice rules.
- Local Verification Needed
40 CFR 745.85(a): Work practice standards: Standards for renovation activities
40 CFR 745 · eCFR 2026-11-19
Covered renovations must be done by certified firms using certified renovators, with warning signs, containment, restricted practices and cleaning as listed.
Edition and verification details
Verified at the state or federal level. Your local permitting office may adopt or amend it differently. Federal rule. State programs can add to it or run their own version. Federal rule for paid renovation in pre-1978 target housing and child-occupied facilities. Some states and tribes run EPA-authorized programs with their own certification.
- Jurisdiction
- Federal
- Source
- Lead-Based Paint Poisoning Prevention in Certain Residential Structures
- Edition
- eCFR 2026-11-19
- Section
- 40 CFR 745.85(a)
- Effective
- Not on file
- Last verified
- Nov 22, 2026
- Trades
- exterior-remodeling, general-contracting, handyman, interior-remodeling, painting, siding, windows-doors
- Page
- Online regulation: cite by section and paragraph; there are no page numbers.
Official sourceReport a problem
Report a problem
Available Minnesota codes
Residential
International Residential Code
2018 · in effect Mar 31, 2020
Official reference availableOfficial source
Minnesota Rules (State Building Code)
2020 Minnesota State Building Code · in effect Mar 31, 2020
Searchable hereOfficial sourceSearch this code
EPA Lead Renovation, Repair and Painting Rule (40 CFR Part 745)
eCFR 2026-11-19
Searchable hereOfficial sourceSearch this code
Building
International Building Code
2018 · in effect Mar 31, 2020
Official reference availableOfficial source
Minnesota Rules (State Building Code)
2020 Minnesota State Building Code · in effect Mar 31, 2020
Searchable hereOfficial sourceSearch this code
Minnesota Rules (State Building Code)
2020 Minnesota State Building Code · in effect Mar 31, 2020
Searchable hereOfficial sourceSearch this code
Electrical
Minnesota Rules (State Building Code)
2026 NEC adoption · in effect Aug 17, 2026
Searchable hereOfficial sourceSearch this code
National Electrical Code (NFPA 70)
2026 · in effect Aug 17, 2026
Official reference availableOfficial source
National Electrical Code (NFPA 70)
2023
Official reference availableOfficial source
Mechanical / fuel gas
International Mechanical Code
2018 · in effect Apr 6, 2020
Official reference availableOfficial source
Minnesota Rules (State Building Code)
2020 Minnesota State Building Code · in effect Apr 6, 2020
Searchable hereOfficial sourceSearch this code
Energy
International Energy Conservation Code
2012
Official reference availableOfficial source
Minnesota Rules (State Building Code)
2015 residential energy code (2012 IECC)
Searchable hereOfficial sourceSearch this code
Worker safety
OSHA Construction Standards (29 CFR Part 1926)
eCFR 2026-11-19
Searchable hereOfficial sourceSearch this code
OSHA Recordkeeping and Reporting (29 CFR Part 1904)
eCFR 2026-11-19
Searchable hereOfficial sourceSearch this code
OSHA-approved State Plan
eCFR 2026-11-19
Searchable hereOfficial sourceSearch this code
Other
FMCSA Motor Carrier Safety Regulations (49 CFR)
eCFR 2026-11-19
Searchable hereOfficial sourceSearch this code
More sources being verified (plumbing, fire). Some states leave these codes to cities and counties.
Learn it
Flashcards, quizzes and practice exams on jobsite safety, codebook navigation, Minnesota permits and the Minnesota Residential Code and running a contracting business.
How answers work
- Answers come only from official sources we have checked. We never make up code text, section numbers, page numbers or dates.
- Copyrighted model codes (like the IRC and IBC) are cited by section and linked to the official copy. We don't reproduce them.
- A statewide result is not a full local compliance check. Your city, township or county can add requirements.
Educational information only. Building codes and licensing requirements vary by jurisdiction and may change. Verify requirements with the applicable authority having jurisdiction before beginning work.